N550M
Nicholas Beazley NB-3G FAA →
reservations
aircraft radio
1 past record
earlier registrations
1 past record
service difficulty reports
9 reports
- 3 Apr 2014
Clutch, failed
DURING FLIGHT, THE LT ENGINE ALTERNATOR STOPPED PRODUCING POWER DUE TO THE DRIVE CLUTCH SLIPPING. AFTER LANDING, REMOVED ALTERNATOR AND CHECKED THE DRIVE…
- 15 Mar 1996
Actuator, freeze up
TRIM ACTUATOR FREEZING UP AT ALT. IN COLD WEATHER CONDITIONS, 10 DEGREES FAHRENHEIT OR SO.
- 13 Mar 1996
Flap Drive, failed
LOST USE OF FLAP SYSTEM DUE TO BROKEN SHAFT OR BAD CLUTCH IN POWER DRIVE UNIT. UNIT FAILED DUE TO ACTUATORS BINDING UP BY FREEZING TEMP AT ALTITUDE. UNITS…
- 13 Mar 1996
Actuator, freeze up
PART WOULD NOT PASS TESTING FOLLOWING SIL 1125-27-082 R2 FREEZE-UP TEST. ACTUATE GREASE IN WORM GEAR DRIVE TO MIX PC-10. FREEZE TO MINUS 50 DEGREES FAHRENEIT,…
- 13 Mar 1996
Actuator, freeze up
PART WOULD NOT PASS TESTING FOLLOWING SIL 125-27-082 R2 FREEZE TEST. ACTUATE GREASE TO MIX THE PC-10 IN WORM GEAR DRIVE FULL TRAVEL. FREEZE TO MINUS 50…
- 13 Mar 1996
Actuator, freeze up
PART WOULD NOT PASS TESTING FOLLOWING SIL 1125-27-082 R2 FREEZE TEST. ACTUATE GREASE MIXTURE PC-10 IN GEAR WORM DRIVE FULL TRAVEL, FREEZE TO MINUS 50 DEGREES…
- 13 Mar 1996
Actuator, sheared shaft
FLAP POWER DRIVE UNIT FAILED. NR 3 ACTUATOR PN 674D100-18 RIGHT SIDE HAD HIGH INPUT TORQUE WHEN COLD-SOAKED FOLLOWING SIL 1125-27-082. CHANGED POWER DRIVE…
- 13 Mar 1996
Actuator, defective
ACTUATOR WAS SHIPPED AS A SERVICEABLE UNIT. TEST PER SIL 1125-27-082 R2. ACTUATED WORM GEAR DRIVE TO MIX THE PC-10 GREASE, FULL TRAVEL BOTH DIRECTIONS. FROZE…
- 13 Mar 1996
Actuator, freeze up
ACTUATOR WAS SHIPPED AS A SERVICEABLE UNIT. TEST PER SIL 1125-27-082 R2 ACTUATED WORM GEAR DRIVE TO MIX PC-10. FULL TRAVEL, BOTH DIRECTIONS. FROZE TO MINUS 50…