N525AS
2009 Boeing 737-890 standard FAA →
registration
- 2009
aircraft radio
1 past record
service difficulty reports
87 reports
- 25 Sep 2025
Battery, inoperative
BOTH L1 AND R1 EE LIGHT BATTERIES ARE DEAD. GROUNDED - YES. REMOVED AND REPLACED BOTH L1 AND R1 EE LIGHT BATTERIES, OPS CHECK GOOD IAW B737-800 AMM…
- 9 Sep 2025
Baffle, cracked
UPON REMOVAL OF BAFFLE CLIP, FOUND BAFFLE CRACKED STA 500F TO 500G LBL25. GROUNDED - YES. REMOVED & REPLACED BAFFLE IAW B737-800 SRM 53-30-53-2R-1.
- 3 Sep 2025
Baffle, corroded
7 EACH RH BAFFLES STA 500A - 500H ARE CORRODED AT NUTPLATE HOLES. GROUNDED - YES. REMOVED & REPLACED 7EA BAFFLES STA 500A TO 500H IAW B737-800 SRM…
- 28 Aug 2025
Fitting, corroded
GIRT BAR FITTING CORRODED STA 312 LBL 55. GROUNDED - YES. REMOVED CORROSION ON GIRT BAR FITTING STA 312 LBL 55 AND FOUND TO BE OUT OF LIMITS IAW B737-800 SRM…
- 28 Aug 2025
Floorbeam, corroded
FLOORBEAM STA 947 CORRODED LBL 4. GROUNDED - YES. REPAIRED FLOORBEAM STA 947 LBL 4 IAW SRM 53-70-31-2R-8W=1 O=.080 R=.160 L=1 D=.020.
- 28 Aug 2025
Floorbeam, cracked
FLOOR SUPPORT CRACKED STA 540 LBL 2. GROUNDED - YES. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02-0G-0.
- 28 Aug 2025
Floorbeam, corroded
AFT WET AREA FLOORBEAM CORRODED STA 986 LBL 50. GROUNDED - YES. REMOVED DAMAGE WITH SURFACE BLEND FOUND TO BE OUT OF LIMITS AND REPAIRED FLOORBEAM IAW SRM…
- 28 Aug 2025
Support, corroded
AFT WET AREA WEB SUPPORT CORRODED STA 990 RBL 40. GROUNDED - YES. REMOVED CORROSION ON WEB SUPPORT STA 990 RBL 40 AND FOUND TO BE OUT OF LIMITS IAW SRM…
- 28 Aug 2025
Floorbeam, cracked
FLOORBEAM CRACKED STA 540 RBL 2. GROUNDED - YES. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02-OG-O.
- 28 Aug 2025
Floorbeam, corroded
AFT WET AREA FLOORBEAM STA 986 CORRODED RBL 50. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED DAMAGE AREA IAW SRM…
- 28 Aug 2025
Support, corroded
AFT WET AREA WEB SUPPORT CORRODED, BS 990, LBL 40. GROUNDED - YES. REMOVED DAMAGED WITH SURFACE BLEND. FOUND TO BE OUT OF LIMITS. REMOVED AND WEB SUPPORT IAW…
- 28 Aug 2025
Intercostal, corroded
UPON REMOVAL IN TRANSITION PANEL FOUND INTERCOSTAL STA 747-767 RBL24 TO BE CORRODED. GROUNDED - YES. FOUND TO BE OUT OF LIMITS REMOVED & REPLACED INTERCOSTAL…
- 28 Aug 2025
Seat Track, corroded
SEAT TRACK STA 540 TO 727B LIGHT GOUGING AND CORRODED RBL 45. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT LIMITS IAW SRM 53-00-52-1A-1 REMOVED &…
- 27 Aug 2025
Skin, cracked
RIGHT HORIZONTAL STABILIZER LOWER SKIN IS CRACKED AT IB SIDE OF RIB 6 STA 129.50 8 IN FROM LE. GROUNDED - YES. CUT OUT DAMAGE AND REPAIRED LOWER SKIN IAW…
- 27 Aug 2025
Skin, cracked
RIGHT HORIZONTAL STABILIZER LOWER SKIN IS CRACKED AT IB SIDE OF RIB 7 STA 138.70, 10 IN FROM TE. GROUNDED - YES. CUT OUT DAMAGE AT STA 138.7 AND ADDITION…
- 26 Aug 2025
Shield, corroded
SHIELD PANEL AFT OF FWD PIT DOOR CUTOUT IS CORRODED. GROUNDED - YES. REMOVED CORROSION ON SHIELD PANEL IN FWD CARGO STA 500-500A R/H AND FOUND TO BE OUT OF…
- 26 Aug 2025
Shield, corroded
AFT PIT RBL 22 RH FWD SHIELD IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED SHIELD IAW BOEING 737-800 SRM 51-40-02-OG-OW:.800 O:.050 R:.015 L:1.2 D:.035.
- 26 Aug 2025
Attach Angle, corroded
AFT PIT RH FWD SHIELD LOWER ATTACH ANGLE IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED ATTACHED ANGLE IAW BOEING 737-800 SRM 51-40-02-OG-OW:.500 O:.050…
- 26 Aug 2025
Transition Panel, corroded
FWD PIT L/H TRANSITION HAS MULTIPLE AREAS OF CORROSION FROM STA 500C TO 500I. GROUNDED - YES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM…
- 26 Aug 2025
Transition Panel, corroded
LEFT TRANSITION PANEL HAD CORROSION FROM BS 727 - 847. GROUNDED - YES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED & REPLACED THE TRANSITION…
- 26 Aug 2025
Transition Panel, corroded
RIGHT TRANSITION PANEL HAD CORROSION BS 727 - 767. GROUNDED - YES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED & REPLACED TRANSITION PANEL IAW…
- 26 Aug 2025
Floor Support, corroded
AFT CARGO FLOOR STRUCTURE, RT INTERCOSTAL STA 727A-727B HAS CORROSION AT NUTPLATE HOLE. VIEW UNDER TRANSTIION PANEL. GROUNDED - YES. FOUND TO BE OUT OF…
- 26 Aug 2025
Angle, cracked
FWD PIT CRACKED BAFFLE CLIP ON FWD SIDE FRAME STA 500G LBL25. GROUNDED - YES. REMOVED & REPLACED BAFFLE CLIP IAW B737-800 SRM 51-40-02-0G-0.
- 26 Aug 2025
Shield, corroded
SHIELD PANEL FWD OF FWD PIT DOOR CUT OUT HAS CORROSION. GROUNDED - YES. REMOVED CORROSION, ON SHEILD PANEL IN FWD CARGO STA 420-440 RH & FOUND TO BE OUT OF…
- 26 Aug 2025
Transition Panel, corroded
FWD CARGO RT TRANSITION HAS MULTIPLE AREAS OF CORROSION FROM STA 500A TO 500I. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW B737-800 SRM…
- 26 Aug 2025
Track, cracked
RH FLOOR TRACK IS CRACKED STA 727G-727J. GROUNDED - YES. REMOVED DAMAGE & REPAIRED IAW B737-800 SRM 53-00-53-2R-3 STEP 4.A-R.
- 2 May 2025
Power Supply, inoperative
AFT GALLEY EXIT LOCATOR SIGN AND L2/R2 OVER DOOR EXIT SIGNS AND L2/R2 EXIT INDICATOR SIGNS INOP. -4APR676B A&P#: 4936657. GROUNDED - YES. (RESOLVED ON W/O:…
- 13 Dec 2024
Light, broken
EMERGENCY EXIT LIGHT COVER BROKEN ROW 16F. GROUNDED - YES. REMOVED & REPLACED EMERGENCY EXIT SIGN ASSY. ROW 16F REF. AMM 33-51-01 EMERGENCY LIGHTS OPS. CHECK…
- 13 Dec 2024
Power Supply, inoperative
FOUND MID EXIT EMERGENCY DOOR LIGHT INOP. GROUNDED - YES. REMOVED AND REPLACED L/H FWD MID EXIT DOOR EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06. OPS CHECK…
- 21 Oct 2024
Light, missing
FLOOR LIGHTING STRIP MISSING NEAR L1 DOOR, 2" INCH. GROUNDED - YES. REMOVED AND REPLACED FIRST 6FT SECTION OF PHOTOLUMINESCENT STRIP AT FWD LEFT OF CABIN…
- 31 Aug 2024
Skin, corroded
BETWEEN STA 905 AND STA 927 BETWEEN STGR 21L AND STGR 22L TOILET VENT HAS SIGNS OF CORROSION GROUNDED - YES. ACCOMPLISHED FUSELAGE SKIN DOUBLER REPAIR BETWEEN…
- 31 Aug 2024
Skin, corroded
FWD OF STA 1088 AND AT STGR 25R FWD END OF APU DOOR HAS SIGNS OF CORROSION. GROUNDED - YES. ACCOMPLISHED CATEGORY A MINOR REPAIR ON FUSELAGE SKIN SECTION 48…
- 31 Aug 2024
Skin, corroded
AT STA 967 BETWEEN SGTR 24R AND STGR 25R HAS SIGNS OF CORROSION ON LOWER FWD CORNER OF THE POWERED OUTFLOW VALVE. GROUNDED - YES. ACCOMPLISHED CATEGORY A…
- 31 Aug 2024
Skin, corroded
STGR 23L FROM STA 727F TO STA 827 HAS SIGNS OF CORROSION. GROUNDED - YES. ACCOMPLISHED CATEGORY A MINOR REPAIR ON FUSELAGE SKIN LAP SEAL STA 727F TO STA 827…
- 12 May 2024
Lens, detached
FLIGHT ATTENDANT REPORTS EMERGENCY EXIT LIGHT COVER FROM SEAT 17A HAS COME OFF. GROUNDED - YES. REPLACED EXIT LIGHT ASSY AT 17A. REF AMM 33-51-01.
- 23 Sep 2023
Power Supply, inoperative
ALL EMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1675 ARE INOP. GROUNDED - YES. REMOVED AND REPLACED M1675 POWER SUPPLY & INSTALLATION TEST GOOD IAW…
- 23 Sep 2023
Power Supply, inoperative
ALL EMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1676 ARE INOP. GROUNDED - YES. REMOVED AND REPLACED POWER SUPPLY M1676 AND OPS CHECK GOOD IAW ASA…
- 23 Sep 2023
Power Supply, inoperative
ALL BATTERY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1671 ARE INOP. GROUNDED - YES. REMOVED AND REPLACED POWER SUPPLY M1671 AND OPS CHECK GOOD IAW ASA…
- 13 Sep 2023
Skin, cracked
R/H HORIZONTAL STABILIZER LOWER SKIN HAS A CRACK INDICATION LOCATED AT STAB. STA. 147.90, 8" FWD OF THE REAR SPAR. APPROX. 1.2" IN LENGTH. (AS MARKED).…
- 27 Feb 2023
Unknown, unknown
L1 DOOR DIFFICULT TO OPEN, WITH RESISTANCE. GROUNDED - YES. CLEARED DEBRIS FROM L1 DOOR HINGES, OPS CHECK GOOD PER B737-800 AMM 52-11-00/601.
- 28 Feb 2022
Bulb, inoperative
FWD CEILING EMERGENCY LIGHT INOP. GROUNDED - YES. RELAMP AND OPS CHECKED IAW B737-800 AMM 33-51-00-710-801. OPS TEST GOOD.
- 6 Feb 2022
Lens, missing
EMERGENCY EXIT LIGHT COVER AT SEAT 17F MISSING. GROUNDED - YES. INSTALLED OVERWING EMERGENCY EXIT COVER IAM B737-800 AMM TASK 33-51-00-710-801. A/C OK OK FOR…
- 15 Oct 2021
Skin, cracked
CRACK INDICATION FOUND BETWEEN STAB STA. 111.10 TO 120.30 APROX. 1" LONG. CRACK ENDS AND LENGHT MARKED IN RED ON R/H H-STAB LOWER SKIN. GROUNDED - YES.…
- 15 Oct 2021
Skin, cracked
CRACK INDICATION FOUND BETWEEN STAB STA. 138.70 TO 147.90 ON R/H H-STAB LOWER SKIN APROX. 1" LONG. CRACK ENDS AND LENGHT MARKED IN RED. GROUNDED - YES.…
- 15 Oct 2021
Skin, cracked
2 CRACK INDICATION FOUND BETWEEN STAB STA. 129.50 TO 138.70 ON THE L/H SIDE H-STAB LOWER SKING.CRACK #1 APROX. 1.15" LONG.CRACK #2 APROX. 1.25" LONG.BOTH…
- 22 Oct 2019
Battery Pack, inoperative
ROW 6 THRU 11LH EMERGENCY EXIT LIGHTS ON BINS INOP. GROUNDED - YES. REMOVED; REPLACED EMERGENCY EXIT BATTERY PACK M2335 S/N 64028. OPS CHECK GOOD IAW ASA…
- 19 Oct 2019
Bulb, burned out
R2 DOOR EXTERIOR EMERGENCY LIGHT INOP GROUNDED - YES. R2 EXTERIOR LIGHT RELAMPED, OPS CHECK GOOD IAW AS B737-800 AMM 33-51-04-960-801
- 5 Oct 2019
Floor Support, gouged
MAIN CABIN UNDER FLOOR INTERCOSTAL HAS GOUGE AROUND HOLE AT BS418 BL0. GROUNDED - YES. REMOVED INTERCOSTAL ANGLE IAW B737-800 SRM 51-40-02. LOCATED, DRILLED…
- 5 Oct 2019
Floor Support, cracked
MAIN CABIN UNDER FLOOR INTERCOSTAL IS CRACK BETWEEN BS380 AND BS400 LBL13. GROUNDED - YES. REMOVED AND REPLACED UPPER CHORD 143A5410-174 REF BAC DWG 143A5400…
- 4 Oct 2019
Floor Support, cracked
INTERCOSTAL CRACKED BS 312 - 328 LBL50. GROUNDED - YES. REMOVED CRACK INTERCOSTAL IAW SRM 51-40-02-06-0, LOCATED AND DRILLED NEW INTERCOSTAL IAW B737-800 SRM…
- 3 Oct 2019
Channel, corroded
"Z" CHANNEL BETWEEN FRAMES 767/787 RIGHT - SURFACE CORROSION ON PREVIOUS BLEND OUT REPAIR. DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED DAMAGE ON AFT…
- 3 Oct 2019
Channel, corroded
Z CHANNEL FWD OF FRAME 787 LEFT SMALL AREA OF SURFACE CORROSION. DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED DAMAGED Z CHANNEL SECTION FROM STA. 727…
- 1 Oct 2019
Web, corroded
AFT PIT LOWER MAIN SILL THRESHOLD WEB HAS SEVERAL SPOTS OF CORROSION BETWEEN BS800 - BS840. GROUNDED - YES. REMOVED CORROSION ON AFT PIT LOWER MAIN SILL…
- 20 Aug 2019
Door Sill, corroded
R2 DOOR JUST INBD OF GIRT BAR FITTING CORRODED AT AFT FASTENER HOLE. GROUNDED - YES. REMOVED CORROSION, CORROSION FOUND TO HAVE 100% MATERIAL LOSS AND OUT OF…
- 27 Jul 2019
Roller, detached
UNABLE TO CLOSE R2 WINDOW (FO SIDE). GROUNDED - YES. FOUND FORWARD LOWER ROLLER CAME OFF. REINSTALLED SAME R2 WINDOW REF AMM 56-12-11-400-801. LOWER ROLLER…
- 2 Mar 2019
Light, inoperative
LT AFT DOOR SLIDE EMERGENCY LIGHT INOP. GROUNDED - YES. RE-LAMPED LT AFT DOOR SLIDE EMERGENCY LIGHT REF AMM 33-51-04-960-801OPS CHECK GOOD.
- 1 Jul 2018
Roller, detached
FO WINDOW HARD TO CLOSE. GROUNDED - YES. FOUND ROLLER ON FO'S SLIDING WINDOW AFT LOWER BELL CRANK HAS FALLEN OFF. REINSTALLED ROLLER PER AMM 56-12-11-820-801.…
- 30 Jun 2018
Lens, missing
AFT RIGHT HAND EMERGENCY EXIT DOOR LOWER EMERGENCY LIGHT ASSEMBLY COVER MISSING. GROUNDED - YES. INSTALLED NEW COVER ASSEMBLY FOR EXIT LIGHT ASSEMBLY, L1188…
- 13 May 2018
Light, smoke
FIRST OFFICER'S CONTROL YOKE LEFT HORN FLIGHT NUMBER LIGHT STARTED SMOKING ON SHORT FINAL. NOTICED A BURNING ELECTRICAL ODOR 10 MINUTES OUT FROM LANDING. ACFT…
- 10 Oct 2017
Bulkhead Web, cracked
LEFT MLG WW BS 663, LBL 48 BULKHEAD WEB FOUND CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE BULKHEAD WEB IAW SRM 51-40-02, DWG 111A1000 REV F, AND DWG…
- 6 Aug 2017
Power Supply, no test
WHILE PERFORMING T/C 78233001 EMERGENCY LIGHTING OPS CHECK, FOUND BATTERY PACKS M1674, FAILED TO TEST. ACFT GROUNDED. POWER SUPPLY REMOVED AND REPLACED FOR…
- 28 Mar 2017
Lens, missing
R2 DOOR EXIT SIGN LENS MISSING. ACFT GROUNDED. REPLACED THE LENS, OK FOR SERVICE.
- 12 Feb 2017
Lamp, failed
R2 DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. ACFT GROUNDED. REPLACED THE LAMPS IAW AMM 33-51-04. OPS CHECKED GOOD.
- 6 Nov 2016
Sign, detached
R2 DOOR EXIT SIGN DETACHED. ACFT GROUNDED. ATTACHED THE EXIT SIGN. OK FOR SERVICE.
- 27 Jun 2016
Lens, missing
F/A REPORTS EXIT LIGHT COVER IS MISSING ON WALL NEXT TO R2 DOOR. ACFT GROUNDED. REPLACED EXIT LIGHT COVER. ACFT OK FOR SERVICE.
- 30 Mar 2016
Light, broken
ROW 17DEF EMERGENCY EXIT LIGHT ASSY BROKEN. ACFT GROUNDED. REPLACED ROW 17DEF FLOOR EXIT LIGHT ASSY. ROW 17DEF FLOOR SIDEWALL EMERGENCY LIGHT OPS NORMAL REF…
- 5 Dec 2015
Spring, disconnected
L1 DOOR STUCK OPEN, ACFT GROUNDED. FOUND GUIDE ARM HOLD OPEN MECHANISM SPRING DISCONNECTED FROM CAM. RECONNECTED SPRING TO CAM MECHANISM ON L1 DOOR AMM…
- 17 Oct 2015
Support Bracket, cracked
FWD PIT LT SIDE UNDER TRANSITION PANEL INTERCOSTAL SUPPORT BRACKET CRACKED AT BS 500H BETWEEN STR 25L AND STR 26L. ACFT GROUNDED. REMOVED FWD PIT INTERCOSTAL…
- 17 Oct 2015
Support Bracket, cracked
FWD PIT LT SIDE UNDER TRNSITION PANEL INTERCOSTAL SUPPORT BRACKET CRACKED AT BS 500H + 2 STR 25L AND STR 26L. ACFT GROUNDED. REMOVED FWD PIT LT TRANSITION…
- 16 Oct 2015
Channel, corroded
AFT CARGO COMPARTMENT RT TRANSITION PANEL IS CORRODED FROM BS 727H TO BS 727J+8. ACFT GROUNDED. REMOVED CORROSION AFT CARGO COMP. RT TRANSTION PANEL. FROM BS…
- 15 Oct 2015
Floorbeam, punctured
MAIN CABIN BS 540, LBL 24 TO LBL 45 PANEL BREAK PLATE IS PUNCTURED. ACFT GROUNDED. R & R MAIN CABIN BS 540, LBL 27 TO LBL 45 PANEL BREAK PLATE IAW SRM 51-40-02.
- 14 Oct 2015
Floor Support, cracked
MAIN CABIN FLOOR STRUCTURE BS 344- BS 360, LBL 11 HAS A CRACKED INTERCOSTAL. ACFT GROUNDED. R & R INTERCOSTAL IAW SRM 51-40-02 AND DWG 141A5410, REV IR. DOT…
- 14 Oct 2015
Floor Support, cracked
MAIN CABIN FLOOR STRUCTURE BS 277-BS 294, BL 0 HAS A CRACKED INTERCOSTAL. ACFT GROUNDED. R & R INTERCOSTAL IAW SRM 51-40-02 AND DWG 141A5400, REV. DOT REMOVED.
- 14 Oct 2015
Floor Support, cracked
MAIN CABIN FLOOR STRUCTURE INTERCOSTAL FROM BS 312-BS 328 AT LBL 46 IS CRACKED. ACFT GROUNDED. R & R INTERCOSTAL IAW SRM 51-40-012 AND DWG 141A5400, REV . DOT…
- 27 May 2015
Arm, loose
R-1 DOOR DIFFICULT TO CLOSE. ACFT GROUNDED. FOUND CENTERING GUIDE ARM ASSY ROD END BEARING IPS 52-41-11-07, ITEM 125 WORN. FOUND R-1 DOOR GUIDE ARM AND…
- 25 Feb 2015
Skin, cracked
CRACK FOUND AT STAB STA 137, 24 1/2' AFT OF FRONT SPAR, APPROX 1' IN LENGTH. LH. GROUNDED - YES. REMOVED DAMAGE & REPAIRED L/H STAB STA 137 LOWER SKIN IAW…
- 25 Feb 2015
Skin, cracked
2 CRACKS FOUND AT STABILIZER STA 100, FIRST IS 28' FROM FWD SPAR APPROX 1' IN LENGTH, SECOND IS 37' FROM FWD SPAR APPROX 1' IN LENGTH, RT. ACFT GROUNDED.…
- 17 Jun 2014
Skin, cracked
CRACK INDICATION ON RT HORIZONTAL STAB LOWER SKIN FWD OF REAR SPAR 1.850", 3.800" INBD OF STAB STA 120.30. CRACK LENGTH TWO INCHES LONG. ACFT GROUNDED.…
- 14 Jun 2014
Seat Track, cracked
CRACK INDICATIONS AT BS727B SPLICE FWD SEAT TRACK FASTENER HOLES, RBL 24.75, HOLE MARKED, INBD AFT AT 3 O'CLOCK POSITION. ACFT GROUNDED. WARNING: THIS…
- 14 Jun 2014
Seat Track, cracked
CRACK INDICATIONS AT BS727B SPLICE FWD SEAT TRACK FASTENER HOLES, RBL 45.50, 2 EA HOLES MARKED, OTBD FWD AT 11 O'CLOCK POSITION,I/B AFT AT 2 O'CLOCK POSITION.…
- 14 Jun 2014
Seat Track, cracked
CRACK INDICATIONS MARKED AT BS727B SPLICE FWD SEAT TRACK FASTENER HOLE, LBL 24.75, OTBD FWD LOCATION AT 7 O'CLOCK POSITION. ACFT GROUNDED. WARNING: THIS…
- 14 Jun 2014
Seat Track, cracked
CRACK INDICATIONS MARKED AT BS727B SPLICE FWD SEAT TRACK FASTENER HOLES, LBL 45.50, 3 EA HOLES MARKED, OTBD FWD AT 11 O'CLOCK POSITION, INBD FWD AT 5 O'CLOCK…
- 13 Jun 2014
Power Supply, failed
EMERGENCY LIGHTS POWER SUPPLY M1673 REQUIRES REPLACEMENT. ACFT GROUNDED. R & R M1673 EMERGENCY LIGHTS POWER SUPPLY, REF: AMM 33-51-06-960-806 EMERGENCY LIGHTS…
- 5 Apr 2014
Skin, cracked
LEFT HORIZONTAL STABILIZER LOWER SKIN CRACKED. ACFT GROUNDED. PERFORMED HFEC, AN 0.8" CRACK NOTED. SKIN REPAIRED.
- 14 Mar 2014
Wire, damaged
FOUND EMERGENCY AREA LIGHT INOPERATIVE AT ROW 6 AND 9 RT SIDE. ACFT GROUNDED. FOUND WIRES W0130-0001/ 0002-20 INSULATION MISSING AT LT ASSY L1065. REQUIRES…
- 31 Jan 2014
Skin, cracked
RT HORIZONTAL STAB HAS TWO CRACKS ON LOWER SURFACE. ACFT GROUNDED. REMOVED THE DAMAGE AT BOTH CRACK LOCATIONS IAW SRM 55-10-01-2R-11, REPAIR 11, STEP 4, B2, A…
- 9 Jan 2012
Unknown, unknown
AFT EMERG EXIT SIGN ABOVE R2 IS OUT. ALSO FOUND EMERGENCY LIGHT ABOVE 15F WINDOW EXIT IS FLICKERING. COULD NOT DUPLICATE PROBLEM EMERGENCY LIGHT ABOVE 15F…