N522AT
1999 Socata TBM 700 standard FAA →
registration
- 1999
aircraft radio
earlier registrations
1 past record
- 2013
service difficulty reports
96 reports
- 19 Feb 2008
Wire, disconnected
EMER FLOOR LIGHTING ROWS 15 THRU 21 INOPERATIVE. T/S FOUND WIRING DISCONNECTED AT ROW 21. RECONNECTED WIRES, OPS CHECKS GOOD. (K)
- 4 Feb 2008
Wire, disconnected
EMERGENCY ESCAPE PATH LIGHT AT ROW 16, 17, AND 20, INOPERATIVE. FOUND WIRE DISCONNECTED AT ROW 20, RECONNECTED WIRE IN PLACE, OPS CHECK NORMAL. (K)
- 3 Feb 2008
Display, intermittent
CENTER LWR CDU (EICAS) GOES DIM AND BLANKS OUT COMPLETELY. INTERMITTENT OPERATION. REPLACED LWR CDU, OPS CHECK NORMAL IAW MM. (K)
- 29 Jan 2008
Lens, missing
SEATS 17DEF, 20DEF, 28DEF, AND 7DEF EGRESS LENSES MISSING. REPLACED MISSING EGRESS LENS ROWS 17, 20, 28 AND 7DEF, OK FOR SERVICE. (K)
- 25 Jan 2008
Apu, oil consumption
DUE TO HISTORY OF APU USING EXCESSIVE OIL, APU IS CONSIDERED INOPERATIVE. APU OIL CONSUMPTION RATE 0.274 QTS PER HOUR, WITHIN THE ETOPS LIMIT IAW GMM CHAPTER…
- 17 Jan 2008
Warning System, activated
(LT IRS FAULT) EICAS MSG COMES ON DURING ROLL OUT AFTER LANDING. (K)
- 16 Jan 2008
Warning System, activated
APU OIL QTY STATUS MSG DISPLAYED. (K)
- 8 Dec 2007
Coupler, unserviceable
LT HF RECEPTION WEAK AT ALL CREW STATION. REMOVED AND REPLACED LT HF COUPLER IAW MM 23-11-01-4, LT HF OPS CHECK NORMAL, CALLED SFO ON 5574, TRANSMITT AND…
- 7 Dec 2007
Coupler, unserviceable
RT HF WILL NOT CHANNELIZE. REMOVED AND REPLACED RT HF COUPLER IAW MM 23-11-01-4, CHANNELIZED AND OPS NORMAL. (K)
- 4 Dec 2007
Symbol Generator, malfunctioned
R SYMBOL GENERATOR FAILED AFTER LANDING. UNABLE TO LOCATE FIRM CODE REASONABLE TIME. RESET AC POWER. OPS CHECKS OK ON GROUND. OK FOR SERVICE. (K)
- 2 Dec 2007
Radio, inoperative
RT HF RADIO W/N CHANNELIZE PROPERLY. WILL NOT TRANSMITT. REOCCURRING PROBLEM. TRANSMITT AND RECEIVE 5X5. OPS CHECKS NORMAL. (K)
- 25 Nov 2007
Transceiver, unserviceable
LT HF DOES NOT RECEIVE AT ANY CREW MEMBER STATION. INSTALLED HF TRANSCEIVER LT SIDE. OPS CHECK GOOD. (K)
- 25 Nov 2007
Transceiver, inoperative
RT HF WILL NOT TRANSMIT EACH TIME MIKE IS KEYED, RT HF CONTINUOUSLY RE-TUNES. PERFORM BITE ON RT HF TRANSCEIVER RESET. OPS CHECK GOOD. (K)
- 23 Nov 2007
Coupler, unserviceable
RT HF TRANSMITTER INOPERATIVE AT ALL CREW STATIONS. REMOVED AND REPLACED RT HF COUPLER IAW MM 23-11-01-4. OPS NORMAL. (K)
- 17 Nov 2007
Radio, malfunctioned
RT HF RADIO WILL NOT CHANNELIZE ON ANY FREQ. RE-RACKED RT HF RT, OPS CK NORMAL. (K)
- 17 Nov 2007
Transceiver, unserviceable
RT HF TRANSMISSION AND RECEPTION INOP AT ALL CREW STATIONS. REPLACED RT HF RT BITE CHECK GOOD. CONTACT, RADIO CHECK GOOD. REM MM 23-11-03. (K)
- 16 Nov 2007
Floor Support, corroded
CABIN FLOOR STRUCTURE UPPER SURFACE HAS CORROSION AT STA 1660 TO 1675, LBL 48. REMOVED CORROSION ON FLOOR SUPPORT STRUCTURE STA 1660-1675, LBL48 IAW SSRM…
- 16 Nov 2007
Floor Support, corroded
CABIN FLOOR SUPPORT STRUCTURE UPPER SURFACE HAS CORROSION FROM STA 1650 TO 1680, RBL 48. REMOVED CORROSION STA 1650-1680, RBL 48 IAW SRM 51-20-01, STA…
- 15 Nov 2007
Warning Message, false activation
(WXR SYS) STATUS MESSAGE DISPLAYED. WX RADAR OPERATES NORMALLY WITH NO FAULTS INDICATED. MSG CLEARED IAW FIM 34- EICAS MESSAGES, WXR SYS OPS NORMALLY. (K)
- 4 Nov 2007
Structure, corroded
FWD CARGO COMPARTMENT RT SIDE WALL TO FLOOR TRANSITION PANEL STRUCTURE, BLOWN OUT CORROSION, STA 620, RBL 30. CUT OUT DAMAGE FROM BS620, RBL 30, NO CORROSION…
- 1 Nov 2007
Intercostal, broken
INTERCOSTAL UPPER ANGLE BROKEN IN 3 AREAS AROUND FASTENER HOLES IN MAIN CABIN AFT FLOOR STRUCTURE BETWEEN FS 1661-1681, RBL 10. REMOVED DAMAGED ANGLE AND…
- 27 Oct 2007
Strap, cracked
STABILIZER STRAP CRACKED AT STA 365.25, WL 208, LBL 25. FABRICATED REPAIR IAW SRM 53-10-51-2R-1, TREATED AND PRIMED IAW SRM 51-20-01, INSTALLED REPAIR AT STA…
- 2 Oct 2007
Coupler, unserviceable
RT HF RADIO WILL NOT TUNE (CONTINUOUS TONE). REMOVED AND REPLACED RT HF COUPLER IAW MM 23-11-01-4, OPS CHECK OK.
- 4 Aug 2007
Radar, malfunctioned
WX RADAR RETURNS HEAVY NOISE AT ALL TILT SETTINGS. OPERATED WXR COULD NOT DUPE, BITE SHOWS NO FAULTS. REPLACED WXR RT IAW AMM 34-43-01-4. WXR CHECKS NORMAL. (K)
- 30 Jul 2007
Charger, unserviceable
EICAS MESSAGE (APU BTY CHARGER). REMOVED AND REPLACED (APU BATTERY CHARGER) IAW MM CH 24-31-04, OPS CHECK GOOD. (K)
- 21 Jul 2007
Transceiver, malfunctioned
RT HF RADIO DOES NOT CHANNELIZE ONLY ABOUT A 15 SECOND LOUD HUM FOLLOWS CHANNELIZATION ATTEMPT. REMOVED AND REPLACED TRANSCEIVER OPS CHECK OK IAW MM 23-11-03.…
- 8 Jul 2007
Coupler, inoperative
HF TRANSMISSION INOPERATIVE AT ALL CREW STATIONS. REMOVED AND REPLACED LT HF COUPLER, OPS CHECK GOOD IAW AMM 23-11-01-4. (K)
- 8 Jun 2007
Apu, unknown
CAPT BRIEFED APU SHUTDOWN TWICE, APU FAULT MSG. (MX MSG) REPLACED APU IAW W/C M57-49-02 AND 49-11-01-4. OPS AND LEAK CHECK GOOD. (K)
- 24 May 2007
Apu, unserviceable
APU AUTO SHUTDOWN. ECU BITE SHOWS (HOT) FAULT. (K) REPLACED APU. OPS AND LEAK CHECK GOOD. (K)
- 15 May 2007
Transceiver, unserviceable
HF TRANSMISSION AND RECEPTION (INOPERATIVE) AT ALL CREW STATIONS. REPLACED RT HF TRANSCEIVER IAW MM 23-11-03. OPS CHECK NORMAL. (K)
- 3 May 2007
Filter, dirty
APU FAILED TO START, APU FAULT MESSAGE - ECU SHOWS LOP SHUTDOWN. FOUND DELTA P ON OIL PRESS FILTER POPPED REPLACED FILTER. RESET DELTA P, RAN APU NO FAULTS…
- 26 Apr 2007
Light, disconnected
FLOOR PATH LIGHTING INOPERATIVE FROM ROW 1-4. RECONNECTED LIGHT ASSY. AT ROW 4. OPS CK GOOD. (K)
- 8 Apr 2007
Wire, disconnected
EMERGENCY FLOOR TRACK LIGHTING 3 DEF THRU 10 DEF INOPERATIVE. INSPECTED FLOOR TRACK WIRING FOUND WIRES DISCONNECTED RESECURED TRACK COVERS, OPS CHECK GOOD. (K)
- 20 Mar 2007
Wire, disconnected
ROW 6-9 EMERGENCY FLOOR LIGHTING INOPERATIVE. RECONNECTED WIRE TO LIGHT ASSY AT ROW 6, OPS CHECK GOOD. (K)
- 15 Feb 2007
Altimeter, inoperative
FO`S ALTIMITER INOPERATIVE. REMOVED AND REPLACED ALTIMITER IAW AMM. OPS CHECKS NORMAL. (K)
- 13 Feb 2007
Computer, malfunctioned
EICAS MSG LT FMC FAIL DISPLAYED OTHER CDU DISPLAYS SINGLE FMC OPERATION MESSAGE. REMOVED AND REPLACED LT FMC IAW MM. CROSS LOAGED. OPS CHECK OK. (K)
- 9 Feb 2007
Actuator, unserviceable
UPON ARRIVAL, APU WOULD NOT START UP AFTER 3 ATTEMPTS. NO OTHER FAULTS, FLAGS OR STATUS MSGS ANNUNCIATED. REMOVED AND REPLACED APU INLET DOOR ACTUATOR IAW MM,…
- 21 Jan 2007
Unknown, unknown
MACH/SPD TRIM EICAS DISPLAYED. PERFORMED RESET PROCEDURE PER FIMM 27-09-00. OPS CHECK NORMAL. (M)
- 28 Dec 2006
Apu, failed
APU FAILED TO START FAULT LGT ILLUM AND EICAS MSG APU FAULT DISPLAYED APU START NORMAL 2ND ATTEMPT. APU FAULT RESET. ECU BITE CARRIED OUT, NO FAULT FOUND. APU…
- 28 Dec 2006
Indication Sys, malfunctioned
LT FUEL TANK AND TOTAL FUEL QTY IND INTERMITTENT EICAS MSG FUEL QTY IND DISPLAYED. DEFERRED IAW MEL 28-41-11, AUTH NR: D28DE29-1406. 07 JAN 07.
- 16 Dec 2006
Processor, unserviceable
LT AND RT FUEL TANK AND TOTAL FUEL QTY INDICATOR BLANK. EICAS MSG FUEL QTY IND DISPLAYED. DISPLAYED RETURNED WITHIN 60 SEC OF FUEL QTY TEST. REPLACED FUEL QTY…
- 12 Oct 2006
Warning System, malfunctioned
EICAS MESSAGE EICAS DISAGREE DISPLAYED EICAS COMPUTER HAS NOT BEEN CHECKED. TROUBLESHOT PER FIM 31-41-00 FIG 103. END RESULT WAS `PROBABLE NUISANCE CONDITION.`
- 3 Oct 2006
Wire, loose
FLOOR TRACK EMERGENCY LIGHTS FROM ROW 6 TO ROW 9 INOPERATIVE DURING TEST. SECURED LOOSE WIRE AT ROW 6 AS REQUIRED. EGRESS LIGHTS OPS CHECK NORMAL PER AMM…
- 3 Oct 2006
Display, failed
FO`S CDU BLANKS OUT OCCASIONALLY SCREEN GOES BLANK FOR ABOUT 3 SEC ONCE PER HOUR. INSTALLED SERVICEABLE FMC CDU PER AMM 34-61-02, CHECK OK. (M)
- 27 Sep 2006
Display, intermittent
NR 1 FMS DISPLAY BLANKS OUT INTERMITTENTLY, DATA IS RETAINED. COULD NOT DUPLICATE DISCREPANCY, SWAPPED LT/RT FMS CDU`S, CDU TESK, OK IAW AMM 34-61-02. (M)
- 13 Sep 2006
Iru, unserviceable
CENTER INU SHOWS IRS MOTION ON FMS CDU WHILE IN NAV DURING TAXI. CENTER IRU REVERTS BACK TO ALIGN MODE. SWAPPED CTR AND RT IRS`S. RT NOW PN HG1050AE09, NS…
- 11 Sep 2006
Display, inoperative
CAPTAIN FMC CDU DISPLAY IS BLANK. REMOVED AND REPLACED FMC CDU DISPLAY. OPS CHECK GOOD PER MM 34-61-02. (M)
- 11 Sep 2006
Pitot Head, unserviceable
F/O PITOT ANNUNCIATOR LIGHT COMES ON INTERMITTENTLY WITH F/O PITOT EICAS MSG. REMOVED AND REPLACED F/O PITOT PROBE PER AMM 34-11-01. LEAK CHECK AND HEATER…
- 3 Sep 2006
Oil System, low
APU FAILED INFLIGHT START. APU OIL LOW, SERVICED APU WITH 3 QUARTS OF OIL. INFLIGHT APU START SUCCESSFUL. (M)
- 9 Aug 2006
Computer, faulty
WITH RT EICAS CMPTR SELECTED, LOWER EICAS DISPLAY GOES BLANK AND GETS EICAS DISPLAY MSG. BOTH DISPLAYS FINE ON L EICAS CMPTR. REPLACED RT EICAS COMPUTER IAW…
- 26 Jul 2006
Iru, malfunctioned
IRS FAULT LIGHT ILLUMINATED ON LANDING (CENTER). UNABLE TO DUPLICATE ON GROUND. IAW GMM CH 8, SWAPPED RT AND CTR IRU`S FOR TROUBLESHOOTING. REMOVAL AND…
- 6 Jul 2006
Panel, unserviceable
CABIN SLOWLY ROSE TO 9500 FT AND SLOWLY RETURNED TO NORMAL CONDITION HAPPENED A SECOND TIME SWITCHED. AUTO 2 PRESSURIZATION STABLE FOR 10-15 MIN CABIN BEGAN…
- 28 Jun 2006
Shutoff Valve, inoperative
AFTER TAKEOFF LT ENG BLEED OFF LITE ON PSI OK. REMOVED AND REPLACED PSOV VALVE IAW MM. OPS CHECK GOOD IAW MM. (K)
- 26 Jun 2006
Boot, loose
LT PACK OFF, PACK FAILED, UNABLE TO MAINTAIN CABIN PRESS WITH RT PACK, OUTFLOW VALVE CLOSED, CL 1200 FPM. RAN BOTH ENGINES, PERFORMED CHECK IAW AMM, NO FAULTS…
- 21 Jun 2006
Iru, malfunctioned
ON TAXI IN THE LT IRS FAULTED. RESET C/B, PERFORMED BITE PROCEDURE IAW FIM, NO FAULTS NOTED, OPS CHECK NORMAL. (K)
- 20 May 2006
Light, inoperative
FLOOR PATH LIGHTS ROW 6-0 AND 1 LIGHT AT RT AFT LAV DOOR INOPERATIVE. RECONNECTED LIGHT ASSY AT ROW 6 AND RELAMPED LIGHT AT LAVE DOOR. ALL OPS CHECKED GOOD. (K)
- 6 Apr 2006
Web, deformed
RT MLG W/W KEEL BEAM WEB, 2 WEB SEGMENTS IMMEDIATELY FWD AND AFT (4 TOTAL SEG BETWEEN VERT STIFFENERS) OF RT MLG DOOR ACTUATOR MOUNT STRUCTURE IS WARPED/…
- 2 Mar 2006
Probe, malfunctioned
LT EEC EICAS MESSAGE. LT EEC INOPERATIVE LIGHT ON OVERHEAD PANEL. TROUBLESHOT IAW FIM. REMOVED AND REPLACED TAT PROBE IAW AMM. OPS CHECK GOOD. OK FOR SERVICE.…
- 21 Dec 2005
Wire, disconnected
EMERGENCY FLOOR TRACK LIGHTING FROM ROW 25 TO RT AFT LAV, INOPERATIVE. RECONNECTED WIRES TO LIGHT ASSY AT ROW 25. OPS CHECK GOOD. (K)
- 23 Nov 2005
Wire, disconnected
ROWS 28, 29 EMERGENCY FLOOR PROX LIGHTING INOPERATIVE. RECONNECTED WIRES TO LIGHT ASSY AT ROWS 28, 29. OPS OK GOOD. (K)
- 13 Nov 2005
Wire, disconnected
3 EACH EMERGENCY LIGHTS OUT AT D LAV TO SEAT 28D. FOUND WIRES DISCONNECTED ON EGRESS RECONNECTED WIRES. OPS CHECKED GOOD. (K)
- 3 Nov 2005
Wire, disconnected
EMERGENCY FLOOR PATH LIGHTING INOPERATIVE AT ROW 28, EXIT MARKER AND 2 LIGHT AT LAV D. RECONNECTED LIGHT ASSY WIRES. OPS CHECK GOOD. (K)
- 19 Oct 2005
Wire, disconnected
ROW 30 EMERGENCY FLOOR PAX LIGHT INOPERATIVE. RECONNECTED WIRES AT ROW 30. OPS CHECK GOOD. (K)
- 14 Oct 2005
Light, disconnected
FLOOR PATH EXIT MARKER, ROW 28, INOPERATIVE. RECONNECTED LIGHT ASSY. OPS CHECK GOOD. (K)
- 9 Sep 2005
Light, inoperative
EMERGENCY LIGHT STRIP NUMEROUS LIGHTS INOPERATIVE FROM SEAT ROW 2FED TO 9FED. REPAIRED EGRESS EMERGENCY LIGHT SYSTEM FROM SEAT ROW 2 DEF TO 9 DEF PER AMM…
- 17 Aug 2005
Bulb, loose
EGRESS LIGHT INOPERATIVE AT 16D AISLE. RESECURED BULB. OPS CHECK GOOD. (K)
- 17 Aug 2005
Socket, disconnected
EGRESS LIGHT INOPERATIVE AT 28D AISLE. FOUND LAMP SOCKET UNPLUGGED. RESECURED AS REQUIRED. OPS CHECK GOOD. (K)
- 8 Aug 2005
Wire, disconnected
SEVERAL EGRESS LIGHTS INOPERATIVE FWD OF L2 DOOR. FOUND WIRE NOT CONNECTED. RECONNECTED AS REQUIRED. OPS CHECK GOOD. OK FOR SERVICE. (K)
- 11 Mar 2005
Light, disconnected
EGRESS LIGHT TRACK AT SEAT 28DEF, HAS 2 LIGHTS INOPERATIVE. FOUND LIGHTS UNPLUGGED. PLUGGED LIGHTS IN IAW MM. OPS CHECK GOOD. (K)
- 27 Jan 2005
Wire, disconnected
EGRESS TRACK LIGHTING AT SEAT ROWS 5-9, INOPERATIVE. CONNECTED WIRING AT ROW 5. OPS GOOD.
- 24 Nov 2004
Connector, unsecure
EGRESS LIGHTS INOPERATIVE FROM ROW 5 THRU ROW 9. FLOOR ESCAPE PATH. SECURED CONNECTOR AT ROW 5 EGRESS LAMP. EGRESS PATH LIGHTING OPS CHECKS GOOD.
- 12 Nov 2004
Wire, disconnected
L2 DOOR EGRESS LIGHTS INOPERATIVE AT ROW 9 R/SIDE (2 EA). RECONNECTED WIRING AT ROW 8 AND 9. OPS CHECK, OK.
- 27 Oct 2004
Skin, chafed
RT WING LWR SKIN, 2 INCHES AFT OF FUEL ACCESS PANEL 641DB, SKIN CHAFED. REWORKED LOWER SKIN AT FUEL ACCESS PANEL 641DB, SKIN CHAFED WAS REPAIRED IAW SRM…
- 19 Oct 2004
Connector, loose
FWD FLOOR TRACK LIGHTING HAS SEVERAL LIGHTS OUT. FOUND LOOSE CONNECTION AT FLOOR TRACK LIGHT INSPECTED AND SECURED. OPERATIONS CHECK GOOD.
- 19 Sep 2004
Crease Beam, corroded
FOUND CORROSION ON CREASE BEAM STATION 1240 RBL 67.5 WL 208. REPAIRED DAMAGE PER SRM 51-70-12 FIG 1. (M)
- 5 Aug 2004
Connector, loose
FOUND EMERGENCY LIGHTS FLOOR PROXIMITY OUT FROM ROW 2 DEF FORWARD. SECURED LOOSE CONNECTOR AS REQUIRED. OPS NORMAL. (M)
- 31 May 2004
Control Unit, failed
L ENGINE AND ENGINE LIMITER INOPERATIVE LIGHT ILLUMINATED. EICAS MSG L ENG EEC, L ENG LIMITER DISPLAYED. REMOVED AND REPLACED BOTH DGCU PER AMM 71-00-00-5…
- 6 Feb 2004
Governor, failed
ENGINE WILL NOT ACCELERATE BEYOND 30 PERCENT N1. REMOVED AND REPLACED LT ENGINE GOVERNOR PER MM 73-21-01-4. (M)
- 27 Oct 2003
Battery, inoperative
R3 EXTERIOR SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY M374 IAW MM 33-51-00. (M)
- 14 Jul 2003
Fitting, leaking
FUEL LEAK, LT ENGINE. ENGINE SHUTDOWN FOR ONE HOUR AND FOUR MINUTES. OIL PRESSURE POSITIVE. RESECURED HIGH PRESSURE FUEL LINE FITTING. LEAK CHECK AND TEST RUN…
- 6 Apr 2003
Light, inoperative
EGRESS FLOOR TRACK INOPERATIVE FROM ROW 35 BACK. REMOVED AND REPLACED LIGHT ASSEMBLY ROW 35 IAW AMM 33-51-11, OPS CHECK NORMAL. (M)
- 15 Mar 2003
Light, inoperative
FOUND TWO EGRESS LIGHTS OUT IN FRONT OF RIGHT AFT LAV DOOR. REPLACED LT SOCKETS AND HARNESS. EGRESS LIGHT CHECKED GOOD. (M)
- 30 Nov 2002
Idg, failed
DURING CRUISE, RECEIVED EICAS MESSAGE GEN DRIVE DISPLAYED, GENERATOR DRIVE LIGHT ILLUMINATED. CREW DISCONNECTED GEN DRIVE. MAINTENANCE REMOVED AND REPLACED…
- 28 Aug 2002
Governor, inoperative
(SUPP-CLOSED) FLIGHT NUMBER 108. RT EEC AND ENGINE LIMITER INOP LIGHT ILLUMINATED. EICAS MESSAGE "RT ENGINE EEC, RT ENGINE" LIMITER DISPLAYED. AIRCRAFT…
- 17 Aug 2002
Engine, overtemp
FLIGHT NUMBER 716. DURING TAKEOFF AT LAS RIGHT ENGINE EGT 855C FOR 15 SECONDS WITH ELC ON, EGT RETURNED TO WITHIN LIMITS WHEN THRUST REDUCED. ENGINE WAS NOT…
- 14 Aug 2002
Engine, overtemp
FLIGHT NUMBER 710. ON TAKEOFF AT LAS THE RIGHT ENGINE EGT REACHED 863 BEFORE PULLING BACK.
- 14 Aug 2002
Bleed Valve, faulty
FLIGHT NUMBER 710. ON TAKEOFF AT LAS RIGHT ENGINE EGT 863C BEFORE PULLING BACK. MAINTENANCE REMOVED AND REPLACED IP BLEED VALVE SOLENOID PER MM 75-32-03-4.
- 13 Aug 2002
Solenoid, malfunctioned
FLIGHT NUMBER 217. DURING GO-AROUND AT LAS, RIGHT ENGINE WENT TO EGT 858. MAINTENANCE REMOVED AND REPLACED LEFT IP BLEED VALVE SOLENOID IN ACCORDANCE WITH MM…
- 13 Aug 2002
Bleed Valve, faulty
FLIGHT NUMBER 217. DURING GO-AROUND AT LAS RIGHT ENGINE WENT TO EGT 858. ENGINE REMAINED 50 DEGREES APPROX WARMER THAN LEFT ENGINE. MAINTENANCE REMOVED AND…
- 10 Aug 2002
Bleed Valve, faulty
FLIGHT NUMBER 716, MAX EPR T/O FROM LAS; RIGHT ENGINE EGT ROSE TO 859C FOR APPROXIMATELY 5 SECONDS. MAINTENANCE REMOVED AND REPLACED HP3 LEFT SOLENOID PER MM…
- 16 Jul 2002
Light, broken
DURING SCHEDULED MAINTENANCE THE OVERHEAD EMERGENCY LIGHT AT ROW 16 DEF WAS FOUND BROKEN. MAINTENANCE REMOVED AND REPLACED ROW 16 DEF AISLE LIGHT PER M/M…
- 19 Feb 2002
Switch, inoperative
UPON SHUTDOWN OF NR 2 ENGINE, EXCESSIVE SMOKE COMING OUT OF INLET AND EXHAUST AREAS. MAINTENANCE FOUND FUEL CONTROL SWITCH FAILED INTERNALLY. SWITCH WAS…
- 14 Nov 2001
Nozzle, cracked
DURING ROUTINE MAINTENANCE AT MDW, THE NR 1 ENGINE COMMON NOZZLE ASSY WAS FOUND TO BE CRACKED AT BOTH INBOARD AND OUTBOARD HOIST ATTACH POINTS. MAINTENANCE…
- 11 May 1999
Fan, inoperative
DURING CRUISE AT FL 41.0, ODOR WAS NOTICED IN AFT GALLEY, SMELLED LIKE PLASTIC MELTING. DIVERTED TO SALT LAKE CITY, WITHOUT FURTHER INCIDENT. FOUND THE NR 4…
- 23 Mar 1999
Backplate, broken
DOOR 4L EVACUATION SLIDE ARMING BACKPLATE BROKEN. RE-EPOXIED ROYALITE COVER ONTO DOOR. OPS CHECK OK.
- 7 Mar 1999
Spinner, iced up
ON CLIMB-OUT, RT ENIGNE N1 VIBS EXCEEDED 4.0 IN AMBER BAND. FOLLOWED FIM 71-05-00, FIG 108, BLK 1 THROUGH BLK 5. PERFORMED TEST NR 6. ALL PARAMETERS .9 AT…