N425FJ
2001 Fairchild Dornier DORNIER 328-300 standard FAA →
reservations
aircraft radio
2 past records
earlier registrations
1 past record
- 2001
service difficulty reports
9 reports
- 12 Oct 2004
Fan, stalled
CAS MESSAGE FOR HX FAN FAILURE WHILE TAXIING. MX REMOVED AND REPLACED FAN.
- 30 Aug 2004
Turbine Blades, damaged
BURNING SMELL ON TAKEOFF. DURING BORESCOPE INSPECTION OF RT ENGINE 1ST STAGE HPT BLADE, MX FOUND LEADING EDGE COATING LOOSE. ENGINE IS BEING CHANGED, WAS BAD…
- 29 Aug 2004
Switch, burned
BURNING ODOR IN CABIN AFTER GEAR RETRACTION. PSBL SMOKE IN CABIN. MECHANIC FOUND DC TIE SWITCH AND RECIRCULATION FAN SWITCH OUT, RESET SWITCHES, PERFORMED OPS…
- 21 Sep 2003
Strut, overserviced
DURING CLIMB THE CREW NOTED A PROXY FAIL CAS MESSAGE. FLIGHT RETURNED TO FIELD AS A PRECAUTION AND AIRCRAFT LANDED UNEVENTFULLY. MAINTENANCE PERSONNEL FOUND…
- 20 Sep 2003
Pseu, faulty
DURING CLIMB THE CREW NOTED A PROXY FAIL AND NLG WOW CAS MESSAGE. EMERGENCY WAS DECLARED AS A PRECAUTION AND AIRCRAFT LANDED UNEVENTFULLY. MAINTENANCE…
- 7 Sep 2003
Power Supply, inoperative
DURING MAINTENANCE INSPECTION THE EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY POWER SUPPLY. A…
- 4 Aug 2003
Connector, loose
DURING MAINTENANCE INSPECTION A FORWARD SECTION OF THE EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL DISCOVERED A LOOSE CONNECTOR AND…
- 30 Jun 2003
Battery Pack, loose
DURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE EMERGENCY FLOOR TRACK LIGHTING WAS INOPERATIVE. MAINTENANCE PERSONNEL SECURED A LOOSE BATTERY PACK. AN…
- 12 Jun 2003
Light, intermittent
DURING PREFLIGHT INPECTION THE CREW REPORTED THAT THE EMERGENCY LIGHT BETWEEN ROWS 4-6, INTERMITTENT. MAINTENANCE PERSONNEL PERFORMED AN OPERATIONAL CHECK AND…