  1. 26 Oct 2004

    Light, inoperative

    Dorner DO328300

    AFT SECTION OF FLOOR EMERGENCY LIGHTS INOPERATIVE. MECHANIC ADJUSTED ELECTRICAL CONTACTS ON EMERGENCY FLOOR LIGHTING.

  2. 21 Aug 2004

    Light, inoperative

    Dorner DO328300

    SECOND CEILING EMERGENCY LIGHT INOP. LIGHT WAS REMOVED AND REPLACED IAW 33-51-04. OPS CHECK GOOD.

  3. 18 Aug 2004

    Pseu, defective

    Dorner DO328300

    DOOR RWP MESSAGE ASSOCIATED WITH CARGO DOOR RED OPEN ON DOOR PAGE. RETURNED TO FIELD. MX RESET PSEU AND INSPECTED CARGO DOOR. NO DEFECT NOTED.

  4. 30 Jul 2004

    Generator, failed

    Dorner DO328300

    LEFT DC GENERATOR FAILURE IN CLIMBING PHASE. PASSENGERS DEPLANED AT THE GATE. ENGINE BEING REMOVED AND REPLACED.

  5. 29 Feb 2004

    Connector, loose

    Dorner DO328300

    DURING INSPECTION THE EMERGENCY ESCAPE PATH LIGHTING AT ROW 9A WAS FOUND INOPERATIVE. A LOOSE CONNECTOR WAS FOUND AND RESECURED. A SATISFACTORY OPERATIONAL…

  6. 4 Feb 2004

    Boot, faulty

    Dorner DO328300

    DURING AIRCRAFT OPERATION THE CREW REPORTED A TAIL DEICE SYSTEM FAILURE. THE EMPENNAGE CROSS BOOT WAS FOUND FAULTY AND REPLACED. A SATISFACTORY OPERATIONAL…

  7. 9 Sep 2003

    Power Supply, inoperative

    Dorner DO328300

    DURING MAINTENANCE INSPECTION THE EMERGENCY LIGHTING WAS FOUND INTERMITTENTLY OPERATING. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE EMERGENCY POWER…

  8. 4 Sep 2003

    Light, disconnected

    Cndair CL6002B19

    DURING MAINTENANCE INSPECTION THE EMERGENCY LIGHT WAS FOUND INOPERATIVE. MAINTENANCE PERSONNEL RE-ATTACHED THE EMERGENCY TRACK LIGHTING AND PERFORMED A…

  9. 28 Jul 2003

    Light, inoperative

    Dorner DO328300

    DURING INSPECTION THE CREW REPORTED THE LAST ONE THIRD EMERGENCY TRACK LIGHTING WAS INOPERATIVE. MAINTENANCE PERSONNEL PERFORMED AN OPERATIONAL CHECK OF THE…

  10. 28 Jun 2003

    Light, inoperative

    Dorner DO328300

    DURING MAINTENANCE INSPECTION, LAVATORY EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED LAVATORY EMERGENCY LIGHT, AN OPERATIONAL…

  11. 17 May 2003

    Connector, loose

    Dorner DO328300

    DURING PREFLIGHT INSPECTION, CREW REPORTED THAT EMERGENCY TRACK FLOOR LIGHTING WAS INOPERABLE. MAINTENANCE PERSONNEL RESECURED A LOOSE CONNECTOR, AN…

  12. 3 Apr 2003

    Light, out of adjust

    Dorner DO328300

    DURING MAINTENANCE INSPECTION CREW NOTED EMERGENCY LIGHTS OUT. MAINTENANCE PERSONNEL ADJUSTED FLOOR EMERGENCY LIGHTS. OPERATIONAL CHECK GOOD AND AIRCRAFT WAS…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05624 Nov 2026
FCC GMRS633,27224 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,84423 Nov 2026
FAA registered aircraft319,59223 Nov 2026
FAA N-number reservations126,12623 Nov 2026
FAA dealers12,51023 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,33524 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.