91 reports
- 16 Mar 2013
Light, out of position
THE CREW REPORTED THE GALLEY FLOOR STRIP LIGHTS WERE OUT OF POSITION. (THE LIGHT COVER) THE ACFT WAS REMOVED FROM SERVICE. REPLACED AND TESTED GALLEY FLOOR…
- 16 Mar 2013
Light, broken
THE CREW REPORTED THE NR 1 FLOOR PROXIMITY EMERGENCY ESCAPE LIGHT WAS BROKEN. REPLACED EMERGENCY LIGHT IAW JIC 33-51-20. OPS CHECKED OK.
- 23 Feb 2013
Engine, failed
CREW REPORTED THAT ON THE ON TAKEOFF ROLL, NR 2 ENGINE TOURQUE WENT TO 95 PERCENT. PREFORMED A HIGH ABORTED TAKE-OFF WHEN SPEED WAS GREATED THAN 70KTS. TAXIED…
- 23 Feb 2013
Engine, unserviceable
THE CREW REPORTED THE FOLLOWING: PREFORMED A HIGH ABORTED TAKEOFF WHEN SPEED WAS GREATED THAN 70KTS. SPEED WAS AROUND 70 KTS, T/O WEIGHT WAS 45886. ON INITIAL…
- 13 Feb 2013
Bulb, loose
THE CREW REPORTED THE EMERGENCY LIGHT ON MAIN ENTRY DOOR WAS INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. REPOSITIONED MAIN ENTRY DOOR FLOOD LIGHT BULB .…
- 7 Feb 2013
Cover, damaged
THE CREW REPORTED THE EMERGENCY FLOOR LIGHT COVER HAS PARTS MISSING. ACFT REMOVED FROM SERVICE. INSTALLED END CAPS IAW MM 33-51-21. OPS CHECKED GOOD. ACFT…
- 15 Jan 2013
Wire Harness, inoperative
THE CREW REPORTED AFTER TAKEOFF, WERE UNABLE TO BRING LANDING GEAR UP. UNABLE TO MOVE GEAR HANDLE FROM DOWN POSITION. CREW DECLARED AN EMERGENCY AND RETURNED…
- 23 Dec 2012
Light, unknown
EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. OPS CHECKED GOOD.
- 21 Oct 2012
Battery Pack, unserviceable
THE CREW REPORTED THE EMERGENCY EXIT LIGHTS REMAINED ON WITH THE SWITCH ON THE ARM POSITION (FIRST HALF REMAINED ON). THE ACFT WAS REMOVED FROM SERVICE. R & R…
- 10 Oct 2012
Cover, missing
THE CREW REPORTED THE EMERGENCY LIGHT COVER IN FRONT OF THE GALLEY IS MISSING. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED THE EMERGENCY LIGHT COVER IN FRONT…
- 22 Sep 2012
Light, inoperative
THE CREW REPORTED THE EMERGENCY EXIT LIGHT IN STAIRS INOPERATIVE. ACFT REMOVED FROM SERVICE. REPOSITIONED PASSENGER/CREW DOOR EMERGENCY LIGHT AND PERFORMED…
- 10 Sep 2012
Guide, corroded
DURING B INSPECTION, FOUND THE LT WING HAS 4 INTERNAL FLAP CAM GUIDES WITH CORROSION OUT OF LIMITS. THE ACFT WAS REMOVED FROM SERVICE. LT WING 4 INTERNAL FLAP…
- 10 Sep 2012
Guide, corroded
DURING B INSPECTION, FOUND THE RT WING HAS 2 EXTERNAL FLAP CAM GUIDES WITH CORROSION OUT OF LIMITS. THE ACFT WAS REMOVED FROM SERVICE. REMOVAL AND…
- 30 Aug 2012
Light, malfunctioned
THE CREW REPORTED THE EMERGENCY LIGHTS ON WITH THE SWITCH ON THE ARM POSITION. THE ACFT WAS REMOVED FROM SERVICE. PERFORMED OPS CHECK OF EMERGENCY LIGHTS AND…
- 24 Aug 2012
Battery, failed
DURING MAINTENANCE INSPECTION, FOUND AN EMERGENCY BATTERY FAULT. THE ACFT WAS REMOVED FROM SERVICE. R & R THE EMERGENCY BATTERY IAW EX-243185-RAI-10020-002.…
- 19 Aug 2012
Cover, broken
CREW REPORTED SERVICE DOOR EMERGENCY LIGHT COVER BROKEN. ACFT REMOVED FROM SERVICE. R & R THE SERVICE DOOR EMERGENCY LIGHT COVER, AS PER 33-50-00. ACFT…
- 12 Jul 2012
Skin, corroded
DURING MX INSPECTION, FOUND THE LT SPOILER UPPER SUFACE METAL STRIP CORRODED AND DEBONDED. THE ACFT WAS REMOVED FROM SERVICE. R & R THE LT SPOILER IAW JIC…
- 4 May 2012
Bulb, loose
THE CREW REPORTED THE FORWARD EXIT EMERGENCY EXIT LIGHT ON LT SIDE OF ACFT IS INTERMITTENT. THE ACFT WAS REMOVED FROM SERIVCE. SECURED LIGHT BULB IAW AMM…
- 17 Apr 2012
Cap, missing
DURING B INSPECTION, FOUND EMERGENCY LIGHT MISSING END CAP AT SEAT 17B. ACFT REMOVED FROM SERVICE. RESECURED EMERGENCY LIGHT END CAP IAW CMM 25-25-03. ACFT…
- 4 Apr 2012
Cap, missing
DURING B-INSPECTION, FOUND THE GALLEY AFT EMERGENCY LIGHT MISSING END CAP. ACFT REMOVED FROM SERVICE. RE INSTALLED END CAP IAW CMM 33-51-01. ACFT RETURNED TO…
- 6 Feb 2012
Switch, unserviceable
ON FLIGHT 4930, THE CREW REPORTED THE EMERGENCY LIGHTS CAME ON DURING ENGINE START AND STAYED ON. THE ACFT WAS REMOVED FROM SERVICE. R & R EMERGENCY TOGGLE…
- 20 Dec 2011
Light, inoperative
EXIT LIGHT OVER FORWARD CABIN DOOR DOES NOT ILLUMINATE. R & R LIGHT IAW AWM 33-51-00. OPS CHECKED GOOD.
- 18 Dec 2011
Contact, corroded
THE CREW REPORTED THE EMERGENCY EXIT LIGHT BELOW LT FWD EMERGENCY EXIT DOOR IS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. CLEANED CORROSION FROM LIGHT…
- 13 Dec 2011
Light, inoperative
2 EMERGENCY FLOOR LIGHTING BY THE GALLEY IS INOPERATIVE. LIGHT INSTALLED AND WORKING PROPERLY IAW JIC 33-50-00, OPS CHECKED GOOD.
- 13 Dec 2011
Light, inoperative
THE CREW REPORTED THE NR 2 EMERGENCY FLOOR LIGHTING BY THE GALLEY IS INOPERATIVE. ACFT REMOVED FROM SERVICE. LIGHT INSTALLED AND WORKING PROPERLY IAW JIC…
- 4 Nov 2011
Connector, damaged
AFTER ENG START, EMERGENCY LIGHTS WERE ON. CYCLED SWITCH LIGHTS AND THEN WORKED PROPERLY. RESECURED CONNECTOR PLUG AT EMERGENCY LIGHT POWER SUPPLY. OPS CK…
- 7 Sep 2011
Light, inoperative
ALL EMERGENCY LIGHTS REMAIN ON AFTER ENGINE START. 1 RESET IS ALWAYS REQUIRED. ALL CIRCUIT BREAKERS CHECKED OK. SEVERAL ENGINE STARTS ACCOMPLISHED WITH…
- 7 Sep 2011
Light, loose
CABIN ENTRANCE DOOR STAIR FLOOD LIGHT APPEARS TO BE LOOSE DURING POSTFLIGHT. ADJUSTED CABIN DOOR EMERGENCY LIGHT BULB HOLDER IAW CMM 33-51-25. OPS CHECKED OK…
- 6 Sep 2011
Light, inoperative
CABIN ENTRANCE DOOR STAIR FLOOD LIGHT INOPERATIVE. REPLACED CABIN ENTRANCE STAIRS FLOOD LIGHT IAW MM 33-51-24. OPS CHECKED OK.
- 3 Jul 2011
Light, inoperative
EMERGENCY FLOOR PATH LIGHT AT THE FWD CABIN AND AFT CABIN DO NOT ILLUMINATE. ONLY MIDDLE ROW OF LIGHTS WORK. AT THIS TIME EMERGENCY FLOOR LIGHT OPERATIONAL…
- 13 Feb 2011
Lamp, burned out
LOWER EXIT SIGN ON SERVICE DOOR NEEDS RELAMPED. RELAMPED LOWER EXIT SIGN IAW MM33-00-00. OPS CHECK GOOD. ACFT RETURN TO SERVICE
- 17 May 2010
Wire, broken
EMERGENCY EXIT LIGHT (BOTTOM ON SERVICE DOOR) INOPERATIVE. FOUND BROKEN WIRE AT PIN NR 1 OF EMER EXIT LT 68WL. RESECURED PIN IAW ASM 33-51-00 OPS CHK GOOD NO…
- 17 Mar 2010
Lamp, failed
EMER EXIT LIGHT AT BOTTOM OF STAIRS IS INOP. RELAMP DOOR LIGHT AND OPT CHECK IAW AMM 33-50-00.
- 27 Sep 2009
Fitting, corroded
LT WING RIB 31 AILERON FITTING HAS CORROSION. REMOVED CORRODED LT WING RIB 31 AILERON FITTING. LOCATED, DRILLED & INSTALLLED NEW FITTING IAW SRM 51-24-08,…
- 22 Sep 2009
Hinge Fitting, corroded
LWR GROUND WIRE ATTACH POINT CORRODED RT FLAP HINGE FITTING RIB 13. REMOVED & REPLACED 2 EA FITTINGS RT WING INBD FLAP OTBD HINGE FITTING IAW SRM 51-21-52 &…
- 21 Jun 2009
Lamp, loose
EMERGENCY LIGHT ON PAX/ENTRY DOOR INOPERATIVE. REPOSITIONED EMERGENCY LIGHT BULB ON PAX/ENTRY DOOR, PERFORMED OPT IAW JIC NR 33-50-000 AND FOUND SYSTEM…
- 18 Jun 2009
Brake Assy, failed
F/O SIDE LEFT SIDE BRAKE PEDAL NO BRAKE WHEN CYCLE. REMOVED AND REPLACED NR 1 BRAKE ASSEMBLY IAW JIC NR 32-42-55. OPT CK GOOD.
- 24 Jan 2009
Lamp, failed
LEFT FORWARD EXTERIOR EMERGENCY FLOOD LIGHT INOPERATIVE. REMOVED AND REPLACED LAMP IAW JIC NR 33-50-00.
- 24 Jan 2009
Lamp, failed
RT AFT EXTERIOR EMERGENCY FLOOD LIGHT INOPERATIVE. REMOVED AND REPLACED LAMP IAW JIC NR 33-50-00.
- 3 Jan 2009
Engine, malfunctioned
LT ENGINE TORQUE WENT TO 95 PERCENT UNCOMMANDED. AWAITING AML PAGE FOR FURTHER DETAILS.
- 23 Nov 2007
Power Supply, discharged
EMERGENCY LIGHT OUT LEFT EXTERIOR FORWARD OF EMERGENCY EXIT. REMOVED AND REPLACED EMERGENCY EXIT POWER SUPPLY AS PER MM 33-51-21.
- 3 Nov 2007
Power Supply, failed
CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHTS POWER SUPPLY 62WL AND PERFORMED OP CK IAW JIC NR 33-50-00.
- 12 Oct 2007
Threshold, corroded
RT THRESHOLD BTW FRAME 36-39 GUTTER CORRODED. RT THRESHOLD BTW FRAME 36-39 GUTTER REPLACED IAW SRM 51-25-01.
- 12 Oct 2007
Floorbeam, corroded
FLOORBEAM 39 CORRODED ON UPPER AND LOWER SURFACE. CORROSION OF FLOORBEAM 39 REPAIRED IAW SRM 53-00-00 FIGURE 450 AT 2 LOCATIONS.
- 12 Oct 2007
Support Bracket, corroded
FWD "T" BRACKET OF FOLDING STEP CORRODED. FWD "T" BRACKET OF FOLD ONG STEP REPLACED IAW SRM 51-25-04.
- 13 Jul 2007
Lamp, inoperative
F/A REPORTED EMERGENCY EXIT FORWARD TOP LIGHT INOPERATIVE WHEN ACTIVATED THE SYSTEM AND BATTERY POWER WAS OFF. MAINTENANCE RE-LAMPED LIGHT AND PERFORMED…
- 6 Mar 2007
Light, inoperative
PERFORMING POST FLIGHT CREW NOTED LT FWD EMERGENCY FLOOD LIGHT INOPERATIVE. REPLACED FWD FLOOD LIGHT BULB IAW JIC 33-50-00. (K)
- 21 Dec 2005
Torque Sensor, inoperative
AFTER TAKEOFF AND DURING CLIMBING, THE RT ENGINE STARTED TO FLUCTUATE ABOUT 10 PERCENT. REPLACED NR 2 TORQUE SENSOR. (K)
- 20 Jul 2004
Engine, fire
DURING TAXI, LEFT ENGINE FIRE INDICATOR ILLUMINATED, FIRE EXTINGUISHER DISCHARGED. REPLACED ENGINE. WAITING FOR TEARDOWN REPORT. (M)
- 18 Mar 2002
Light, inoperative
MIA - FLT 4975 - CREW REPORTED THE PASSENGER DOOR EMERGENCY LIGHT TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LIGHT ASSEMBLY IAW ATR MM.…
- 23 Jun 2001
Engine, malfunctioned
MIA - FLT 5420 - ON TAKEOFF, ITT ON NR 2 DURING ROLL WAS 765 DEGREES AND CLIMBING. PULLED NR 2 POWER LEVER BACK 6 DEGREES TORQUE BEFORE IT STOPPED CLIMBING AT…
- 29 Mar 2001
Light, inoperative
MIA - FLT 5409 - EMERGENCY FLOOR LAMP AFT OF GALLEY INOPERATIVE, MEL PER 33-30. REMOVED AND REPLACED BULB IAW AMM. OPS CHECK GOOD. (M)
- 29 Mar 2001
Light, inoperative
MIA - FLT 5409 - FOUND EMERGENCY FLOOR LAMP AFT OF GALLEY INOPERATIVE, MEL PER 33-30. (M)
- 19 Feb 2001
Power Supply, discharged
MIA - FLT 5236 - PASSENGER DOOR EMERGENCY EXIT LIGHT IS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT…
- 26 Jan 2001
Pump, failed
MIA - FLT 5339 - CREW REPORTED AFTER TAKEOFF, THE LANDING GEAR WOULD NOT FULLY RETRACT. CREW ALSO REPORTED A THUMPING NOISE AND RECEIVED A LEFT MLG UNLOCK…
- 11 Jan 2001
Track, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE SERVICE DOOR AND PAX DOOR DRAIN TRACKS CORRODED BETWEEN FRAMES 36 AND 39. MAINTENANCE REMOVED AND…
- 11 Jan 2001
Control Rod, corroded
SAW - DURING HMBV-1 INSPECTION REPORTED, THE LEFT AND RIGHT ELEVATOR TRIM TAB CONTROL RODS CORRODED INTERNALLY. MAINTENANCE REMOVED AND REPLACED THE CONTROL…
- 11 Jan 2001
Control Rod, corroded
SAW - DURING HMBV-1 INSPECTION REPORTED, THE LEFT AND RIGHT ELEVATOR TRIM TAB CONTROL RODS CORRODED INTERNALLY. MAINTENANCE REMOVED AND REPLACED THE CONTROL…
- 11 Jan 2001
Sill, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE PAX DOOR SILL PLATE CORRODED BETWEEN FRAMES 36 AND 39. MAINTENANCE REMOVED AND REPLACED THE SILL…
- 11 Jan 2001
Floorbeam, cracked
SAW - DURING CPCP-8 INSPECTION, MAINTENANCE REPORTED THE LEFT SIDE OF FLOORBEAM 34 HAD A CRACK IN A HI-LOCK HOLE. MAINTENANCE REPAIRED FLOORBEAM 34 IAW SRM…
- 11 Jan 2001
Floor Support, corroded
SAW - DURNIG CPCP-8 INSPECTION, MAINTENANCE REPORTED THE FLOOR BOARD SUPPORT PLATE AT FRAME 13 RIGHT CORRODED. MAINTENANCE REMOVED AND REPLACED THE SUPPORT…
- 11 Jan 2001
Track, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE SERVICE DOOR AND PAX DOOR DRAIN TRACKS CORRODED BETWEEN FRAMES 36 AND 39. MAINTENANCE REMOVED AND…
- 11 Jan 2001
Structure, corroded
SAW - DURNG CPCP-2 INSPECTION, MAINTENANCE REPORTED THE RIGHT AFT ZEE MEMBER BETWEEN FRAMES 39 AND 42 CORRODED. MAINTENANCE REMOVED AND REPLACED THE ZEE…
- 11 Jan 2001
Floor Support, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE LEFT FLOOR SUPPORT BETWEEN FRAMES 39 AND 40 CORRODED. MAINTENANCE REMOVED AND REPLACED THE FLOOR…
- 9 Jan 2001
Flap, corroded
SAW - DURNIG MBV-2 INSPECTION, MAINTENANCE REPORTED ALL SIX CAM GUIDES, NR 2 AND NR 6 CAM GUIDE ATTACH BRACKETS, OUTBOARD BEAM ATTACH BRACKETS, AND THE MIDDLE…
- 9 Jan 2001
Guide, corroded
SAW - DURING MBV-2 INSPECTION, MAINTENANCE REPORTED THE NR 1, NR 2 AND NR 3 CAM GUIDES CORRODED ON THE LEFT INBOARD FLAP. MAINTENANCE REMOVED AND REPLACED THE…
- 9 Jan 2001
Guide, corroded
SAW - DURING MBV-2 INSPECTION MAINTENANCE REPORTED, THE NR 1, 2, 3, AND NR 4 CAM GUIDES CORRODED ON THE RIGHT INBOARD FLAP. MAINTENANCE REMOVED AND REPLACED…
- 17 Dec 2000
Bracket, broken
SAV - FLT 5342 - AFTER TAKEOFF, CREW TRIED TO SELECT GEAR UP AND FOUND THE HANDLE WOULD NOT MOVE. MAINTENANCE FOUND A NOSE LANDING GEAR PROXIMITY SWITCH…
- 15 Dec 2000
Battery Pack, discharged
MIA - FLT 5276 - FORWARD CABIN DOOR EXIT AND CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT 61WL POWER SUPPLY. OPS CHECK GOOD. (M)
- 27 Nov 2000
Fuse, inoperative
MIA - EMERGENCY LIGHT IN PASSENGER STAIRS INOPERATIVE. REPLACED FUSE IN 62WL POWER SUPPLY. OPS CHECKED GOOD IAW JIC 33-50-00-OPT-10000-004. (M)
- 8 Oct 2000
Light, inoperative
MIA - FLT 5322 - PASSENGER DOOR EMERGENCY LIGHT ON THE STAIRS IS INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK GOOD. (M)
- 9 Jan 2000
Guide, corroded
SAW - DURING MBV-2 INSPECTION MAINTENANCE, REPORTED THE NR 3, NR 4 AND NR 5 CAME GUIDES CORRODED ON THE RIGHT OUTBOARD FLAP. MAINTENANCE REMOVED AND REPLACED…
- 18 May 1999
Floorbeam, elongation
SAW - DURING CPCP-4 INSPECTION, FOUND FLOORBEAM 18 HAD AN ELONGATED HI-LOCK HOLE. REPAIRED FLOORBEAM 18 IAW SRM 53-00-00 FIGURE 429. AIRCRAFT RETURNED TO…
- 18 May 1999
Skin, canning
SAW - DURING MBV-1 INSPECTION, MAINTENANCE REPORTED OIL CANNING OF LEFT FUSELAGE SKIN BETWEEN FRAME 9 AND 10 AND STRINGER 14 AND 18. MAINTENANCE INSTALLED A…
- 18 May 1999
Seat Track, corroded
SAW - DURING MBV-1 INSPECTION, FOUND LEFT FORWARD INBOARD AND OUTBOARD, LEFT MIDDLE INBOARD AND OUTBOARD, LEFT AFT INBOARD AND OUTBOARD, LEFT AND RIGHT FLIGHT…
- 29 Nov 1998
Mfc, failed
MIA - FLT 5782 - LEFT MAIN LANDING GEAR UNLOCK LIGHT ON OVERHEAD PANEL IS ILLUMINATED. REMOVED AND REPLACED NR 2 MULTIFUNCTION COMPUTER (MFC). GEAR…
- 29 Apr 1998
Floorbeam, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THAT FLOORBEAMS 36 AND 38 WERE CORRODED. MAINTENANCE REMOVED AND REPLACED BOTH FLOORBEAMS IAW SRM…
- 29 Apr 1998
Support, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING ITEMS CORRODED BETWEEN FRAMES 39 AND 41 LEFT SIDE. THE LEFT Z-MEMBER, WEB, FLOOR CHANNEL…
- 29 Apr 1998
Support, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING ITEMS CORRODED BETWEEN FRAMES 39 AND 41 LEFT SIDE. THE LEFT Z-MEMBER, WEB, FLOOR CHANNEL…
- 29 Apr 1998
Support, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING ITEMS CORRODED BETWEEN FRAMES 39 AND 41 LEFT SIDE. THE LEFT Z-MEMBER, WEB, FLOOR CHANNEL…
- 29 Apr 1998
Web, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THE FOLLOWING ITEMS CORRODED BETWEEN FRAMES 39 AND 41 LEFT SIDE. THE LEFT Z-MEMBER, WEB, FLOOR CHANNEL…
- 29 Apr 1998
Floorbeam, corroded
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPORTED THAT FLOORBEAMS 36 AND 38 WERE CORRODED. MAINTENANCE REMOVED AND REPLACED BOTH FLOORBEAMS IAW SRM…
- 29 Apr 1998
Skin, dented
SAW - DURING CPCP-2 INSPECTION, MAINTENANCE REPAIRED DENT ON RIGHT SIDE OF FUSELAGE ABOVE NLG WELL AT FRAME 3 WL 2327.5. MAINTENANCE REPAIRED DENT IAW SRM…
- 19 Jan 1998
Battery, discharged
EMERGENCY LIGHTING INOPERATIVE, 66WL POWER SUPPLY CONTROLS THEM. REPLACED BATTERY PACK AT 66WL POWER SUPPLY IAW JIC 33-51-21 SATISFACTORILY AND RETURNED…
- 19 Jan 1998
Battery, discharged
LBB - EMERGENCY BATTERY PACK AT 61WL HAS EVIDENCE OF POSSIBLE HEAT DAMAGE. REPLACED BATTERY PACK AT 61WL. OPS CHECK GOOD IAW JIC 33-51-21 SATISFACTORILY AND…
- 6 Nov 1997
Reading Light, burned
ORD - FLT 4280 - ON APPROACH FOR LANDING IN SBN, FLIGHT ATTENDANT NOTED SMOKE IN THE AREA OF THE READING LIGHTS AT SEATS 1DC. FLIGHT ATTENDANT SELECTED BOTH…
- 2 May 1997
Power Supply, inoperative
DFW - FLT 3651 - F/A REPORTS EMERGENCY EXIT LIGHTS (FWD/AFT CABIN) CAME ON DURING TAXI. RAI'D POWER SUPPLY AT 73WL FOR EMERGENCY LIGHT SYSTEM. (M)
- 18 Feb 1997
Battery Pack, discharged
DFW - DURING ROUTINE A-CHECK, FOUND FORWARD PAX COMPARTMENT EMERGENCY LIGHTS WOULD NOT ILLUMINATE. RAI'D EMERGENCY LIGHT PACK AT 61 WL IAW ATR 72 JIC…
- 7 Feb 1997
Battery Pack, discharged
ORD - FLT 4321 - EMERGENCY EXIT LIGHT OVER NR 2 FLIGHT ATTENDANTS SEAT INOP. AIRCRAFT WAS RETURNED TO SERVICE. (M)
- 24 Oct 1996
Fan, failed
FLT 3677 - FLIGHT DIVERTED TO BGS WITH SMELL AND VISIBLE SMOKE IN COCKPIT AND CABIN. EMERGENCY WAS DECLARED AND AIRCRAFT LANDED WITHOUT INCIDENT. AT DFW,…
- 29 May 1996
Garlock Seal, torn
DFW - FLT 3620 - NR 2 ENGINE LOST OIL PRESSURE WITH ALL WARNINGS. CREW SHUT DOWN ENGINE AND LANDED WITHOUT INCIDENT. REMOVED AND INSTALLED AC WILD GENERATOR…