N311FL
1997 Raytheon Aircraft Company HAWKER 800XP standard FAA →
registration
- 1997
aircraft radio
earlier registrations
1 past record
- 1990
service difficulty reports
71 reports
- 11 Aug 2016
Starter Gen, failed
DECLARED AN EMERGENCY DUE TO THE NR 2 GENERATOR FAILING IN FLIGHT WITH AN ASSOCIATED VIBRATION AND LOUD NOISE. CONDUCTED AN INFLIGHT SHUT DOWN OF THE NR 2…
- 1 Dec 2014
Fitting, cracked
THE PASSENGER ENTRY DOOR FORWARD HANDRAIL ATTACH FITTING ON DOOR WAS FOUND CRACKED AND PEELED BACK, WITH UPPER RIVET ATTACHING THE FITTING TO THE DOOR…
- 16 Jan 2013
Control Cable, chafed
DURING A SCHEDULED INSPECTION, MX FOUND THE ELEVATOR CABLES TO HAVE CHAFE MARKS, PN: 505-15041-403 & 505-15042-403. LOCATION OF CHAFE MARKS WERE IN THE…
- 24 Oct 2012
Starter Gen, vibration
THE CREW ADVISED AT FL450 THEY EXPERIENCED A HIGH VIBRATION FROM THE NR 2 ENGINE ACCOMPANIED BY A NR 2 GENERATOR FAILURE, THE CREW FOLLOWED THE CHECKLIST FOR…
- 12 Jul 2011
Skin, cracked
DURING INSPECTION OF ENGINE INLETS, CRACKS AND MISSING/DAMAGED FASTENERS WERE FOUND ON THE LT ENGINE INLET. THE FASTENERS WERE REPLACED. ADDITIONAL C/A…
- 12 Jul 2011
Skin, cracked
DURING INSPECTION OF ENGINE INLETS, CRACKS AND MISSING/DAMAGED FASTENERS WERE FOUND ON THE RH ENGINE INLET. THE FASTENERS WERE REPLACED. ADDITIONAL CORRECTIVE…
- 7 Jul 2005
Skin, dented
FUSELAGE SKIN HAS DENT AT BS 480 S-26R - S-28R.
- 7 Jul 2005
Stringer, cracked
STRINGER 27R CRACKED.
- 7 Jul 2005
Skin, cracked
FUSELAGE EXTERNAL SKIN CRACKED AT S-24R BETWEEN BS 727D - 727E.
- 7 Jul 2005
Skin, dented
DENT AT RT EXTERNAL FUSELAGE AT BS 871 BETWEEN S-22R AND S-23R.
- 6 Jul 2005
Frame, cracked
BS 178 BULKHEAD RT SIDE AFT SIDE FRAME HAS EVIDENCE OF CRACK ABOVE AND BELOW WL 207.
- 6 Jul 2005
Bulkhead, cracked
CRACK APPROX. 5.5 INCHES BELOW WL 207 IB SIDE LBL 5.7 APPROX. 1.2 INCH IN LENGTH AT BS 178 BULKHEAD.
- 6 Jul 2005
Bulkhead, cracked
CRACK APPROX 8 IN BELOW WL 207 INBD SIDE RBL 5.7 APPROX 1.5" IN LENGTH AT BS 178 BULKHEAD.
- 6 Jul 2005
Skin, dented
DENT 3 IN DIAMETER, DEPTH .015 INCHES FUSELAGE S 1070 S-14L FRONTIER DENT TALLY ITEM NR 3.
- 6 Jul 2005
Skin, dented
DENT AT RT EXTERNAL FUSELAGE SKIN AT BS 391.5 BETWEEN S-22R AND S-23R.
- 6 Jul 2005
Skin, dented
DENT AT LT EXTERNAL FUSELAGE SKIN AT BS 997.5 BETWEEN S-13L AND S-14L.
- 6 Jul 2005
Skin, dented
DENT AT RT EXTERNAL FUSELAGE SKIN AT BS 876 S-21R AND S-22R.
- 30 Jun 2005
Skin, dented
DENT IN LEFT FUSELAGE EXTERIOR SKIN BS 935 S-26L.
- 30 Jun 2005
Skin, dented
CREASES IN DENTS AND ON TOP OF STRINGER 27R AT BS 951 - 952 A/Y = 24.7 A/Y 1.875 X .076.
- 30 Jun 2005
Skin, dented
CREASE IN DENT AT BS 971 BETWEEN S-24L-25L 2 INCHES X .86 A/Y = 23.3. S/O NR 109002, OPS NR 25863.
- 27 Mar 2005
Hinge Fitting, cracked
INSPECTION REPORTED R1 DOOR UPPER HINGE ARM FITTING CRACKED. DOOR FRAME CRACKED AT HINE ARM CUTOUT. REPLACED R1 DOOR UPPER HINGE CASTING PER SRM 51-40-02 AND…
- 8 Mar 2004
Floorbeam, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT CABIN FLOORBEAM AT STA 986 CORRODED. CORROSION ON FLOORBEAM TOP FLANGE FOUND TO BE OUT OF LIMITS PER SRM 53-60-31.…
- 8 Mar 2004
Screw, loose
DURING C-7 CHECK, INSPECTION REPORTED SCREWS F2 AND F4 WERE FOUND LOOSE PER RUDDER INSPECTION PERFORMED PER EO B3-55-00AD-0001-DY, PART 2, STEPS 2 AND 4.…
- 8 Mar 2004
Support, corroded
DURING C-7 CHECK, INSPECTION REPORTED LT AFT GALLEY WALL SUPPORT CORRODED AT STA 989, LBL 44. REPLACED SUPPORT PER SOPM 20-41-02 AND SRM 51-40-02.
- 8 Mar 2004
Frame, cracked
DURING C-7 CHECK, INSPECTION REPORTED BODY FRAME CRACKED AND BENT IN FWD CARGO COMPARTMENT AT STA 460, STR 28R. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED…
- 3 Mar 2004
Floorbeam, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT GALLEY FLOORBEAM CORRODED ON WEB AND UNDER GALLEY ATTACH POINT, RT SIDE, STA 986, RBL 42. BLENDED CORROSION ON WEB…
- 3 Mar 2004
Web, corroded
DURING C-7 CHECK, INSPECTION REPORTED L-2 DOOR WEB CORRODED FROM STA 949 TO STA 991.5. FABRICATED AND INSTALLED REPLACEMENT WEB PER SRM 51-40-02, 53-60-51,…
- 3 Mar 2004
Support, corroded
DURING C-7 CHECK, INSPECTION REPORTED LT AFT GALLEY WALL SUPPORT CORRODED AT STA 989, LBL 44. REPLACED WALL SUPPORT PER SOPM 20-41-02 AND SRM 51-40-02.
- 3 Mar 2004
Floorbeam, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT FLOORBEAM AT STA 947 CORRODED ALONG GOUGE 20 INCHES EITHER SIDE OF CENTER LINE. REPLACED T-CAP PER EA B3-53R-10330…
- 3 Mar 2004
Floor Support, corroded
DURING C-7 CHECK, INSPECTION REPORTED FLOOR SUPPORT CORRODED AT NUT PLATE HOLES, RBL 51, STA 947 TO STA 967, WL 208. REPLACED FLOOR SUPPORT PER SRM 51-40-2…
- 3 Mar 2004
Floorbeam, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT GALLEY FLOORBEAM WEB CORRODED AT STA 986.5, LBL 42. FABRICATED AND INSTALLED REPLACEMENT WEB PER SRM 53-60-51,…
- 3 Mar 2004
Sill, corroded
DURING C-7 CHECK, INSPECTION REPORTED SILL PLATE AT L2 DOOR FLOOR CORRODED. REPLACED MOP SILL PER SRM 51-10-02.
- 3 Mar 2004
Floorbeam, corroded
DURING C-7 CHECK, INSPECTION REPORTED FLOORBEAM AT STA 950, RBL 26 TO RBL 49, WL 208 CORRODED AT FLOORBOARD HOLES. FABRICATED AND INSTALLED REPLACEMENT…
- 3 Mar 2004
Channel, corroded
ZEE CHANNEL AT STA 993, LBL 30 TO LBL 40 CORRODED. FABRICATED AND INSTALLED REPLACEMENT Z-CHANNEL PER SRM 51-10-02, PAGE 37, SRM 51-30-01 AND SOPM 20-41-02.
- 20 Feb 2004
Web, corroded
DURING C-7 CHECK, INSPECTION REPORTED RT TOILET SUPPORT WEB CORRODED. BLENDED CORROSION, FOUND TO BE OUT OF LIMITS PER 737-300 SRM 53-60-51. REMOVED RT AFT…
- 20 Feb 2004
Web, corroded
DURING C-7 CHECK, INSPECTION REPORTED LT TOILET SUPPORT WEB CORRODED. CORROSION FOUND TO BE OUT OF LIMITS PER 737-300 SRM 53-60-51. REMOVED DAMAGED LT AFT…
- 19 Feb 2004
Sill, corroded
DURING C-7 CHECK, INSPECTION REPORTED L1 DOOR MOP SILL CORRODED THE WIDTH OF THE DOORWAY AND EXTENDING AFT TO THE END OF THE CORD. REPLACED MOP SILL IAW SRM…
- 11 Feb 2004
Skin, cracked
DURING C-7 CHECK, INSPECTION REPORTED RT FUSELAGE SKIN CRACKED AT LOWER AFT CORNER OF R-1 DOOR CUTOUT. REMOVED DAMAGED AREA AND REPAIRED PER SRM 53-10-01 FIG…
- 9 Feb 2004
Mount, corroded
DURING C-7 CHECK, INSPECTION REPORTED FWD LAVATORY MOUNT BLOCK AT STA 303, LBL 12, CORRODED. REPLACED LAVATORY MOUNT PER SRM 53-10-15, SRM 53-10-51 AND…
- 5 Feb 2004
Stringer, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOOR STRINGER AND NUT PLATE CORRODED AT STA 727B, STR 2L. REPLACED FLOOR BEAM STRINGER PER SRM…
- 5 Feb 2004
Panel, cracked
DURING C-7 CHECK, INSPECTION REPORTED TRANSITION PANEL IN FWD CARGO COMPARTMENT CRACKED AT NUT PLATE HOLE, STA 430 + 11, BL 24R. FABRICATED AND INSTALLED NEW…
- 5 Feb 2004
Stringer, corroded
DURING C-7 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOOR STRINGER AND NUT PLATE CORRODED AFT OF STA 727A, RT MID STRINGER. REPAIRED AFT CARGO…
- 28 Jan 2004
Skin, cracked
DURING C-7 CHECK, INSPECTION REPORTED RT AFT FUSELAGE SKIN CRACKED JUST BELOW EMERGENCY LIGHT AT STA. 727, STR. 25R. CUT OUT DAMAGED SKIN. FABRICATED AND…
- 19 Dec 2003
Spindle, worn
INSPECTION REPORTED EXCESSIVE PLAY AND WEAR IN RT OB NR 8 FLAP CARRIAGE SPINDLE. REPLACED SPINDLE, SPINDLE BEARING AND BUSHINGS AND FLAP SADDLE.
- 11 Apr 2003
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORTS BETWEEN STA. 847 AND 867. FABRICATED AND INSTALLED REPAIR PER SRM 53-00-53.
- 11 Apr 2003
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT AT STA. 772, BETWEEN RBBL 8.10 AND LBBL 12.5. FABRICATED AND INSTALLED REPAIRS PER SRM…
- 11 Apr 2003
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT AT STA. 727D + 5. FABRICATED AND INSTALLED REPAIR PER SRM 53-00-53.
- 14 Mar 2002
Stringer, cracked
DURING C-5 CHECK, INSPECTION REPORTED CRACK ON STRINGER 6L, STA 798.
- 6 Mar 2002
Floor Panel, cracked
DURING C-5 CHECK, INSPECTION REPORTED CRACK IN FWD CARGO COMPARTMENT FLOOR PANEL AT STA 490, STR 26R.
- 22 Oct 2001
Proximity Switch, out of adj
REJECTED TAKEOFF. FLIGHT CREW REPORTED AFT CARGO COMPARTMENT DOOR LIGHT ILLUMINATED UPON REACHING TAKEOFF THRUST. ADJUSTED AFT CARGO COMPARTMENT DOOR…
- 27 Feb 2001
Door Frame, corroded
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT DOOR FRAME CORRODED AT STA 867. MAINTENANCE REMOVED SUPPORT ANGLE, INTERCOSTAL AND TRANSITION WEB…
- 27 Feb 2001
Skin, corroded
DURING C-4 CHECK, INSPECTION REPORTED INTERGRANULAR CORROSION ON INSIDE SKIN OF C2 DOOR CUTOUT, AFT LOWER CORNER. REMOVED CORROSION ON BEAR STRAP PER SRM…
- 22 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO COMPARTMENT FLOORBEAM CORRODED AT STA 847, STR 26R. MAINTENANCE REPLACED FLOORBEAM SUPPORT STRAP AND WEB PER…
- 22 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT CARGO COMPARTMENT FLOOR SUPPORT BEAM AT STA 867, RBL 15. MAINTENANCE REPLACED FLOOR SUPPORT BEAM PER…
- 22 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE FLOORBEAM AT STA 986.5 CORRODED ACROSS TOP. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT FLOOR BEAM PER…
- 21 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM INTERCOSTAL CAP, STA 951.5, BETWEEN 26 LBL AND 50 LBL. MAINTENANCE…
- 21 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE FLOOR SUPPORT CORRODED AT LBL 12, BETWEEN STA 947.5 AND STA 967. MAINTENANCE FABRICATED AND INSTALLED…
- 21 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE FLOOR SUPPORT CORRODED AT LBL 16, STA 950. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT FLOOR SUPPORT…
- 19 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOORBEAM AT STA 947.5. MAINTENANCE REMOVED FLOORBEAM, FABRICATED, TREATED, PRIMED AND…
- 19 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT AT LBL 24, STA 947.5 TO 967. MAINTENANCE REMOVED AFT FUSELAGE FLOOR SUPPORT,…
- 19 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT AT LBL 3, STA 947.5 TO 967. MAINTENANCE REMOVED AFT FUSELAGE FLOOR SUPPORT,…
- 18 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 14 INCHES LT OF CENTER LINE 0, BETWEEN STA 967 AND 986.5. MAINTENANCE INSTALLED…
- 18 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 14 INCHES RBL, BETWEEN STA 967 AND 986.5. MAINTENANCE FABRICATED AND INSTALLED…
- 18 Feb 2001
Web, corroded
DURING C-4 CHECK, INSPECTION REPORTED WEB CORRODED AT LT SIDE OF FUSELAGE, AFT OF STA 986.5, FWD OF PRESSURE WEB. MAINTENANCE FABRICATED AND INSTALLED…
- 18 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FUSELAGE STRUCTURE AT AFT GALLEY LOWER DOOR FRAME, STA 990 - 1006. MAINTENANCE REPLACED MOP SILL AND WEB…
- 18 Feb 2001
Crease Beam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION AT AFT ENTRY DOOR THRESHOLD, STA 986. MAINTENANCE REMOVED CREASE BEAM, CLEANED UPPER AND LOWER SURFACE BELOW…
- 17 Feb 2001
Floor Support, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 2 INCHES FROM LT CENTER LINE 0, BETWEEN STA 986.5 AND 967. MAINTENANCE…
- 13 Feb 2001
Floorbeam, corroded
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM AT STA 967. REPLACED FLOORBEAM CAP AT STA 967 FROM LBL 37.5 TO RBL 36 PER…
- 13 Aug 2000
Floor Panel, cracked
DEN - PRIOR TO DEPARTURE, MAINTENANCE REPORTED HOLE IN AFT CARGO COMPARTMENT FLOOR PANEL NR 2 AND FLOORBEAM AT STATION 747, RBL 19, CRACKED AT TIE DOWN.…
- 14 Feb 2000
Skin, corroded
DEN - DURING C-5 CHECK INSPECTION, FOUND CORROSION ON FORWARD LAVATORY SERVICE PANEL BETWEEN SKIN WHERE DUMP FITTING IS MOUNTED. MAINTENANCE FABRICATED…
- 28 Nov 1999
Actuator, failed
SFO - FLT 653 - DURING APPROACH INTO SFO, FLIGHT CREW REPORTED THE RT MAIN LANDING GEAR WOULD NOT EXTEND. USED ALTERNATE METHOD TO EXTEND GEAR AND GREEN LIGHT…