N293AY
2014 Airbus A330-243 standard FAA →
registration
- 2014
aircraft radio
service difficulty reports
81 reports
- 29 Feb 2020
Oven, odor
AIRCRAFT WAS GROUNDED: DIVERTED TO SCQ. FLT. ATTENDANTS AND F/O REPORTED ACRID ODOR LIKE BURNING WIRES IN AFT GALLEY. PULLED ALL CB'S IN GALLEY.ODOR PERSISTED…
- 5 Dec 2019
Door Sill, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUT OUT LOWER SILL BEAM BETWEEN FR 75 AND FR 76 AND S26R. REPLACED BEAM PER SRM 51-72-11.
- 17 Nov 2019
Floor Panel, damaged
AIRCRAFT WAS GROUNDED: BULK CARGO COMPARTMENT FLOOR PANEL 161CF SOFT. REPLACED FLOOR PANEL PER AMM 53-42-17.
- 14 Nov 2019
Cover, detached
AIRCRAFT WAS GROUNDED: EMERGENCY EXIT LIGHT COVER FELL OFF AT DOOR 3L. MAINTENANCE FOUND BULB WIRES DETACHED. MAINTENANCE REPAIRED SOLDERING THE WIRES TO THE…
- 18 Oct 2019
Damper, low pressure
AIRCRAFT WAS NOT GROUNDED: 3L DOOR DAMPER PRESSURE LOW. MAINTENANCE SERVICED DOOR DAMPER TO PROPER PRESSURE PER AMM 52-22-00.
- 14 Sep 2019
Hinge Bracket, worn
AIRCRAFT WAS GROUNDED: RIGHT MAIN LANDING GEAR HINGED DOOR BRACKET LOOSE / WORN ON MAIN GEAR LEG. REPLACED BRACKET PER CMM 32-12-16 AND EA 298392.
- 1 Aug 2019
Bottle, low pressure
AIRCRAFT WAS NOT GROUNDED: 3L DOOR ASSIST BOTTLE PRESSURE WAS LOW. MAINTENANCE SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE PER 52-22-00-600-801A.
- 26 May 2019
Damper, low pressure
AIRCRAFT WAS NOT GROUNDED: L3 DOOR DAMPER PRESSURE LOW. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-10-00 AND PERFORMED SATISFACTORY OPERATIONAL…
- 22 Apr 2019
Bottle, low pressure
AIRCRAFT WAS NOT GROUNDED: L1 DOOR ASSIST BOTTLE PRESSURE LOW. MAINTENANCE SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE PER AMM 52-10-00 AND PERFORMED…
- 13 Apr 2019
Bottle, low pressure
AIRCRAFT WAS NOT GROUNDED: DOOR L1 ASSIST BOTTLE PRESSURE LOW. MAINTENANCE SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE PER AMM 52-10-00.
- 25 Mar 2019
Bottle, low pressure
L1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. THE AIRCRAFT WAS GROUNDED. MAINTENANCE SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-600-801A, AND PERFORMED A…
- 24 Mar 2019
Bottle, low pressure
CIDS PANEL DISPLAYED THE L1 DOOR HAD LOW PRESSURE. THE AIRCRAFT WAS GROUDNED. MAINTENANCE SERVICED THE L1 DOOR ASSIST BOTTLE IAW JC 33C80052002, AND PERFORMED…
- 24 Mar 2019
Bottle, low pressure
CIDS PANEL DISPLAYED THE L1 DOOR LOW PRESSURE. THE AIRCRAFT WAS GROUNDED. MAINTENANCE SERVICED THE DOOR ASSIST BOTTLE IAW JC 33C80052002, AND PERFORMED A…
- 22 Mar 2019
Sensor, inoperative
AN ECAM BLEED PAGE NR 2 PACK OUTLET TEMPERATURE INDICATION INOPERATIVE. SD PAGE INDICATE XX. AFTER TAKEOFF, THE NR 2 PACK SHUTDOWN AGAIN. THE CREW DECLARED AN…
- 16 Sep 2018
Bottle, low pressure
L1 DOOR ASSIT BOTTLE PRESSURE WAS LOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00-600-802A. AIRCRAFT IS OK FOR SERVICE.
- 29 Aug 2018
Slide, low pressure
R1 DOOR HAD LOW SLIDE PRESSURE. MAINTENANCE CHECKED SLIDE PRESSURE AND PERFORMED SATISFACTORY OPERATIONAL CHECK.
- 28 Aug 2018
Slide, detached
DURING TRANSIT CHECK, FOUND THE L3 DOOR SLIDE DETACHED FROM THE DOOR. THE AIRCRAFT WAS GROUNDED. REPLACED THE DOOR SLIDE IAW JC 33L80025001.
- 28 Aug 2018
Bottle, low pressure
L1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-600-802.
- 28 Aug 2018
Slide, defective
CIDS PANEL SHOWED THE R1 DOOR SLIDE PRESSURE IN AMBER. PRESSURE VISUAL CHECKED OK. REPLACED 1R DOOR ESCAPE SLIDE PER JOB CARD 33L00025001. CIDS PANEL AMBER…
- 25 Aug 2018
Slide, low pressure
R1 DOOR, CHECK PRESSURE INDICATION ON THE FAP. MAINTENANCE REPLACED DOOR ESCAPE SLIDE IAW JC 33L00025001 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.
- 21 Aug 2018
Bottle, low pressure
L1 DOOR DAMPER BOTTLE IN YELLOW. SERVICED L1 DOOR BOTTLE IAW 52-10-00-600-802-A. CHECKED OK, NO LEAKS NOTED.
- 9 Aug 2018
Bottle, low pressure
L1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW MM 52-10-00.
- 30 Jul 2018
Bottle, low pressure
L1 DOOR DAMPER AND EMERGENCY OPS CYLINDER PRESSURE WAS LOW. MAINTNENANCE SERVICED THE DOOR BOTTLE IAW AMM 52-10-00-600-802-A, AND PERFORMED A SATISFACTORY OPS…
- 18 Jun 2018
Sign, damaged
OVERHEAD EMERGENCY EXIT SIGN AT THE L3 DOOR WAS FOUND DAMAGED. REMOVED AND REPLACED THE SIGN IAW AMM 33-51-17. OPS CHECKED GOOD.
- 27 Feb 2018
Sign, detached
EXIT SIGN AT THE L2 DOOR FELL OFF. REPLACED THE DOOR EXIT SIGN.
- 25 Feb 2018
Bottle, low pressure
AIRCRAFT WAS GROUNDED. L1 DOOR ASSIST BOTTLE PRESSURE FOUND TO BE LOWER THAN 1783 PSI. SERVICED L1 DOOR ASSIST BOTTLE.
- 2 Feb 2018
Connector, damaged
SEAT 1H EMERGENCY LIGHT INOPERATIVE. REPLACED THE CONNECTOR BACKSHELL.
- 30 Dec 2017
Lens, detached
EMERGENCY EXIT SIGN LENS AT THE R3 DOOR DETACHED. THE LENS WAS SECURED.
- 19 Dec 2017
Battery, no test
AIRCRAFT WAS NOT GROUNDED. WHILE ACCOMPLISHING JOBCARD 33C22033002, EMERGENCY POWER SUPPLY UNIT BATTERY AT 4L FAILED TEST. REPLACED BATTERY PER AMM 33-51-38.
- 19 Dec 2017
Battery, no test
WHILE ACCOMPLISHING JOBCARD 33C22033002, EMERGENCY POWER SUPPLY UNIT BATTERY AT 2L FAILED TEST. REPLACED THE BATTERY IAW AMM 33-51-38.
- 5 Dec 2017
Lens, loose
AIRCRAFT WAS NOT GROUNDED. EXIT LIGHT LOCATED AT 3L DOOR IS OFF FRAME. RESECURED EXIT LENS.
- 25 Nov 2017
Actuator, failed
AIRCRAFT WAS GROUNDED. R4 DOOR ASSIST ACTUATOR DOES NOT PASS THE BLEED DOWN TEST. REPLACED R4 DOOR ASSIST ACTUATOR.
- 11 Nov 2017
Bottle, leaking
DOOR ASSIST BOTTLE LEAKING ON THE L2 DOOR. REPLACED DOOR ASSIST BOTTLE.
- 22 Oct 2017
Bottle, low pressure
L2 DOOR ASSIST ACTUATOR PRESSURE LOW. SERVICED L2 DOOR ASSIST ACTUATOR BOTTLE.
- 18 Oct 2017
Bottle, low pressure
L2 DOOR DAMPER PRESSURE LOW. SERVICED L2 DOOR DAMPER.
- 14 Oct 2017
Bottle, low pressure
L2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-600-802.
- 6 Oct 2017
Bottle, low pressure
THE L2 DOOR ASSIST CYLINDER PRESSURE WAS IN YELLOW ZONE. CHARGED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.
- 6 Oct 2017
Bottle, low pressure
FOUND THE R4 DOOR BOTTLE PRESSURE LOW. SERVICE THE R4 DOOR BOTTL TO THE PROPER PRESSURE IAW AMM 52-10-00.
- 29 Sep 2017
Bottle, low pressure
L2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED L2 DOOR BOTTLE.
- 19 Sep 2017
Sign, broken
AIRCRAFT WAS NOT GROUNDED. 3R EXIT SIGN FELL OFF. REPLACED 3R EXIT SIGN.
- 7 Sep 2017
Bottle, low pressure
AIRCRAFT WAS NOT GROUNDED. CIDS PANEL MESSAGE CHECK DOOR PRESSURE FOR 2L. SERVICED 2L DOOR PRESSURE.
- 31 Aug 2017
Bottle, low pressure
CIDS PANEL MESSAGE FOR CHECK L2 DOOR PRESSURE. SERVICED THE DOOR ASSIST BOTTLE.
- 29 Aug 2017
Bottle, low pressure
CHECK THE L2 DOOR PRESSURE ON CIDS PANEL. SERVICED L2 DOOR ASSIST BOTTLE.
- 5 Aug 2017
Battery, failed
AIRCRAFT WAS NOT GROUNDED. EPSU BATTERY TEST 11WL FAILED. REPLACED 1L 11WL EPSU BATTERY.
- 2 Aug 2017
Lens, missing
AIRCRAFT WAS NOT GROUNDED. EMERGENCY SIGN 4R MISSING. REPLACED 4R DOOR EMERGENCY EXIT SIGN LENS.
- 29 Jul 2017
Oven, odor
MID-GALLEY OVEN NR 2 INOPERATIVE, SMELLS ELECTRICAL. REPLACED MID GALLEY THE NR 2 OVEN.
- 6 Jul 2017
Wire Harness, disconnected
2A SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. RECONNECTED THE WIRE HARNESS.
- 24 Jun 2017
Bottle, low pressure
AIRCRAFT WAS NOT GROUNDED. 4R DOOR ASSIST BOTTLE LOW. SERVICED DOOR ASSIST BOTTLE.
- 14 Jun 2017
Warning Message, false activation
CHECK DOOR PRESSURE ACTIVATED AT THE R4 DOOR. ACCOMPLISH ESO 52-10-00-2, LEAK CHECKED THE DOOR DAMPER CYLINDER. MAINTENANCE FOUND THE R4 DOOR DAMPER CYLINDER…
- 13 Jun 2017
Cylinder, low pressure
R4 DOOR CHECK PRESSURE LIGHT. SERVICED THE DOOR DAMPER CYLINDER IAW AMM 52-10-00.
- 7 Jun 2017
Bottle, low pressure
CIDS PANEL MESSAGE FOR CHECK THE R4 DOOR PRESSURE. SERVICED THE DOOR ASSIST BOTTLE.
- 7 Jun 2017
Lens, broken
EMERGENCY LIGHT LENS AT THE R2 LAVATORY FELL OFF. REINSTALLED LIGHT LENS COVER.
- 31 May 2017
Cylinder, low pressure
DURING DAILY CHECK FOUND THE R4 DOOR DAMPER CYLINDER PRESSURE OUT OF LIMITS. SERVICED THE CYLINDER. AIRCRAFT WAS GROUNDED.
- 23 May 2017
Damper, low pressure
R4 DOOR ASSIST DAMPER NEEDS SERVICING. SERVICED THE R4 DOOR ASSIST DAMPER.
- 20 May 2017
Cylinder, low pressure
DURING AN ETOPS CHECK, FOUND R4 DOOR CYLINDER PRESSURE LOW. SERVICED THE R4 DOOR DAMPER CYLINDER.
- 4 Mar 2017
Lens, broken
BROKEN EMERGENCY EXIT LIGHT LENS NEAR LAVATORY L37. REPLACED THE LENS AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.
- 19 Feb 2017
Bottle, low pressure
LOW PRESSURE ON R4 DOOR ASSIST BOTTLE. SERVICED R4 DOOR ASSIST PER AMM 52-13-14. ACCOMPLISHED SATISFACTORY OEPRATIONAL CHECK.
- 14 Jan 2017
Battery, discharged
AIRCRAFT WAS NOT GROUNDED. L1 EMERGENCY LIGHT BATTERY FAILED. REPLACED LIGHT BATTERY PER JOB CARD 33C20033002.
- 23 Nov 2016
Unknown, odor
THE FLIGHT EXPERIENCED A DIRTY SOCK SMELL DURING APPROACH. MAINTENANCE ACTION PENDING. THE AIRCRAFT WAS NOT GROUNDED. NO FAULTS WERE NOTED.
- 22 Oct 2016
Lens, missing
R3 CROSS ISLE WALL MOUNTED LIGHT UNIT MISSING LENS COVER. INSTALLED MISSING LENS COVER.
- 4 Aug 2016
Lens, missing
FLOOR EMERGENCY LIGHT LENS MISSING AT LAVATORY L74 AISLE. INSTALLED THE LENS.
- 14 Jun 2016
Air Filter, contaminated
AIRCRAFT WAS NOT GROUNDED: FLIGHT CREW RECEIVED LAV SMOKE ECAM WARNING FOR ABOUT 60 SEC. DETERMINED IT WAS TRIGGERED BY HAIRSPRAY IN LAV 4R AND LINT BUILD-UP…
- 6 Jun 2016
Cover, missing
AIRCRAFT WAS NOT GNDED. LAVATORY L74 EMER LIGHT COVER IS MISSING. REPLACED EMER LIGHT COVER AT LAVATORY L74.
- 2 May 2016
Sign, broken
AIRCRAFT WAS NOT GNDED. EXIT SIGN DOOR 3R BROKEN. REPLACED 3R EXIT SIGN & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-17-400-801A.
- 30 Apr 2016
Flashlight, inoperative
AIRCRAFT WAS NOT GNDED. L2 DOOR FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT.
- 19 Apr 2016
Sign, unsecure
AIRCRAFT WAS NOT GNDED. 3R EXIT SIGN COMING OFF. RE-INSTALLED 3R EXIT SIGN IAW AMM 25-61-00.
- 12 Feb 2016
Lens, missing
AIRCRAFT WAS NOT GNDED. EMER ESCAPE PATH LIGHT AT LT MID LAVATORY L37 MISSING LENS. INSTALLED LENS ON EMER LIGHT AT MID-LAVATORY L37 IAW AMM 33-51-12-400-816.…
- 22 Dec 2015
Battery, unserviceable
AIRCRAFT WAS NOT GNDED. WHILE ACCOMPLISHING JC 33C20033002, FOUND 2 EPSU BATTERIES UNSERVICEABLE, 11WL & 17WL. R & R EPSU BATTERIES AT EPSUS 11WL & 17WL IAW…
- 22 Dec 2015
Battery, unserviceable
AIRCRAFT WAS NOT GNDED. WHILE ACCOMPLISHING JC 33C20033002, FOUND 2 EPSU BATTERIES UNSERVICEABLE, 11WL & 17WL. R & R EPSU BATTERIES AT EPSUS 11WL & 17WL IAW…
- 26 Oct 2015
Engine, leaking
DURING DECENT, CABIN FILLED WITH AN ACRID ODOR. BARELY NOTICED IN THE COCKPIT, BACK VERY STRONG AT REAR GALLEY & BULKHEAD. ODOR RESULTED IN HEADACHES &…
- 3 Jul 2015
Lens, unsecure
EXIT SIGN AT DOOR 3L FELL OFF. R & R EXIT LOCATION SIGN 59WL AT L3 EMER EXIT DOOR IAW AMM 33-51-17. OPERATIONS CHECKED NORMAL.
- 20 Apr 2015
Cover, deteriorated
3L EXIT LIGHT COVER DETERIORATED. INSTALLED LIGHT COVER.
- 5 Mar 2015
Filter Element, dirty
AFTER DEICING & ANTI-ICING, ON TAKEOFF ROLL MASSIVE AMOUNT OF SMOKE IN COCKPIT & CABIN RESULTING IN ABORT. UNABLE TO DETECT ANY ODOR IN ANY BLEED…
- 17 Feb 2015
Lens, unsecure
3L EXIT DOOR FELL OFF, EXIT DOOR LIGHT COVER. REPLACED AFT LENS COVER ABOVE 3L EXIT DOOR.
- 31 Jan 2015
Filter Element, dirty
EN-ROUTE, ON FINAL APPROACH, CREW SMELLED UNUSUAL ODOR IN COCKPIT. FLIGHT ATTENDANTS REPORTING STRONG ODOR THROUGHOUT ENTIRE PLANE. DECLARED AN EMER. AFTER…
- 29 Jan 2015
Cover, unsecure
3L DOOR EXIT LIGHT COVER KEEPS FALLING OFF. SECURED EXIT DOOR LIGHT COVER AS REQUIRED.
- 17 Jan 2015
Power Supply, inoperative
EPSU 14WL REQUIRES REPLACEMENT. R & R EPSU & ITS BATTERY.
- 18 Dec 2014
Sign, unsecure
CABIN 3L DOOR EXIT SIGNS OVERHEAD FELL OFF ON TAKEOFF. REPLACED EXIT SIGNS FOR 3L DOOR.
- 14 Nov 2014
Oven, dirty
FLIGHT ATTENDANT IN REAR GALLEY REPORTED STRONG ODOR, MUSTY SMELL. AT CRUISE, SELECTED HI FLOW PACK & ODOR DISSIPATED. NO SMELL IN REST OF CABIN. REPLACED…
- 6 Sep 2014
Fitting, leaking
FLIGHT 206 WAS FLYING FOR ONE HOUR TWENTY MINUTES WHEN THE CREW ADVISED HE WAS LOSING HYD FLUID FROM THE GREEN SYS. AFTER CONTACTING MAINTENANCE IT WAS AGREED…
- 14 Jun 2014
Slide, unsecure
R2 SLIDE RELEASED FROM DOOR UPON OPENING & RESTED ON CATERING TRUCK, DID NOT DEPLOY. REPLACED THE DOOR SLIDE & DIAPHRAGM. THE ASSIST BOTTLE WAS SERVICED ALSO.