N270RA
1995 Mooney M20M standard FAA →
aircraft radio
1 past record
earlier registrations
1 past record
- 1995
service difficulty reports
8 reports
- 6 Aug 1999
Switch, failed
'GROUND SPOILER' CAUTION (AMBER) MESSAGE ON EICAS WITH FLAPS DOWN. NEW SWITCH CLEARED MESSAGE.
- 11 Jan 1999
Switch, failed
'GROUND SPOILER' CAUTION MESSAGE ON WITH FLAP SELECTION (I.E., FLAPS DOWN INBOARD PUMP OPERATING). NEW SWITCH CLEARED MESSAGE. SUBMITTER STATED THIS IS THIRD…
- 29 Dec 1998
Servo Valve, failed
NOSE WHEEL STEERING FAILS UPON TOUCH-DOWN (RESETTABLE). FAILURE COULD BE INDUCED BY FREEZING THE TORQUE-MOTOR. WHEN STEERING WAS ARMED, NOSE WHEELS TURNED…
- 15 Dec 1998
Pump, failed
APU FUEL PUMP 'FAIL' LIGHT ON. REMOVED FAILED APU FUEL PUMP. INSTALLED REPLACEMENT UNIT. OPERATION NORMAL.
- 15 Dec 1998
Pump, failed
UNIT RECEIVED IN FAILED CONDITION. PREVIOUS TEAR-DOWN REPORT, UNIT INOPERABLE, BLOWN FUSE, BRUSHES WORN UNEVENLY, ARMATURE GROOVED, BRUSHES CHIPPED. UNIT…
- 15 Dec 1998
Pump, failed
UNIT WAS INSTALLED ON AIRCRAFT FOR ONLY 51 HOURS BEFORE FAILURE. (PREVIOUS TEAR-DOWN REPORT READ - 'CAUSE FOR REMOVAL UNCONFIRMED'. CAUSE WAS LISTED AS 'APU…
- 6 Oct 1998
Valve, failed
CABIN TEMPERATURE CONTROL DID NOT WORK ON THE GROUND. WORKED NORMALLY IN-FLIGHT. FOUND TEMPERATURE MODULATING AND SHUT-OFF VALVE CRACKED AT INLET FITTING.…
- 12 May 1998
Switch, failed
DURING TRANSITION FROM CLIMB TO CRUISE FLIGHT, BOTH CHANNELS OF THE HORIZONTAL STABILIZER TRIM CONTROL SYSTEM FAILED. CREW WAS UNABLE TO RE-ENGAGE THE TRIM…