N167AW
1978 Cessna 340A standard FAA →
registration
- 1978
aircraft radio
1 past record
earlier registrations
1 past record
- 2007
service difficulty reports
29 reports
- 23 Mar 2001
Actuator, failed
IAH - EMERGENCY LANDING - 3/18/01 - EN ROUTE FROM PHX TO IAH PRIOR TO DESCENT THE L/E FLAP TRANSIT AMBER LIGHT CAME ON AND REMAINED ILLUMINATED; THE CREW…
- 8 Feb 2001
Stringer, damaged
STR 28L STA 1016 HAS AN ELONGATED BOLT HOLE. REPAIRED IAW SRM 53-00-03 FIG 201 DETAIL V.
- 8 Feb 2001
Stringer, corroded
AFT BULKHEAD STA 1016 CTR STRINGER FOUND CORRODED AT BOTTOM. REPAIRED IAW SRM 51-70-11 FIG 1.
- 8 Feb 2001
Strap, cracked
FLOOR TRACK SUPPORT CRACKED AT STA 717B RBL 45.5. FABED, REPAIRED, AND INSTALLED IAW ER 5310-01010-SSI.
- 29 Jan 2001
Frame, cracked
STA 178 BULKHEAD SKIN CRACKED IN 2 PLACES, INTERCOSTALS (2) CRACKED AT SIDE CHORDS, AND SIDE CHORDS CRACKED AT 3 PLACES STA 178 WL 184 TO 207 LBL 45.50 TO RBL…
- 18 Jan 2001
Frame, cracked
FUSELAGE FRAME ANGLE CRACKED BELOW CABIN FLOOR STA 616 RT, WL 201, RBL 60. REPAIRED AS PER AWA ER 03-5311-01010-JL2.
- 6 Dec 2000
Wire, broken
EMERGENCY LIGHT AT SEAT 2B INOP. REPAIRED BROKEN WIRE, OPERATIONALLY CHECKS GOOD
- 23 Jun 2000
Battery Pack, discharged
EMERGENCY LIGHT OVER L-1 DOOR AND OUTSIDE R-2 DOOR INOPERATIVE. REMOVED AND REPLACED BATTERY AND CHARGER OPS CHK GOOD
- 1 Apr 2000
Circuit Breaker, failed
CO-PILOTS FWD WINDOW HT OVERHEATS AND POPS C/B. HISTORY: WINDOW AND PITOT HEAT MODULE WAS REMOVED AND REPLACED FOR LP 7366891 AND RERACKED FOR LP 636890 ON…
- 8 Feb 2000
Light, inoperative
NON-ROUTINE LINE, EMERGENCY LIGHTING. EMERGENCY EXIT PATH WAY SIGN HAS INOP LIGHTS, AT L-2 DOORWAY. REMOVED AND REPLACED EXIT LIGHT ASSEMBLY, OPS CHECK GOOD.
- 11 Oct 1999
Starter, failed
DURING ENG START GROUND CREW REPORTED ENG NR 2 FIRE. COMPLIED WITH ENG FIRE SERVICE. DAMAGE CHECKLIST FOLLOWED BY QRL CK, NO IND IN FIRE HANDLE. NOTED SPARKS…
- 19 Dec 1997
Battery Charger, inoperative
AFT GALLEY EMERGENCY LIGHT INOP. REPLACED BATTERY CHARGER IN AFT GALLEY, OPS CK GOOD. STC NR SA3432NM
- 9 Aug 1997
Wire, disconnected
DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 2 LEFT EMERGENCY ESCAPE PATH SEAT LIGHT INOP. REPAIRED BROKEN WIRE WITH ENVIRONMENTAL SPLICE ROW 2B. OPS CHECK GOOD.
- 17 Oct 1996
Light, missing
PHX - FLT 2440 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT AT ROW 4 RIGHT MISSING FROM BULLNOSE PANEL. REINSTALLED EMERGENCY EXIT LIGHT.…
- 20 Aug 1996
Sensor, inoperative
LAS - FLT 916 - AIR TURN BACK, LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. FOUND AIR SAFETY GAP NOT PER BMM. REPLACED SENSOR S106 AND ADJUSTED AND TESTED…
- 22 Jul 1996
Light, inoperative
PHX - FLT 2220 - DURING ROUTINE MAINTENANCE CHECK, FOUND R1 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. INSTALLED NEW SOCKET. (X)
- 25 Feb 1996
Fuse, failed
PHX - FLT 0029 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE ON SEATS IN THE FORWARD MID-SECTION. FOUND WIRE TOUCHING GROUND AT…
- 5 Oct 1995
Angle, cracked
PHX - DURING SCHEDULED C10 INSPECTION, FOUND SHEARED RIVETS AND A CRACK IN ANGLE ALONG OUTER EDGE AT WING LOWER SKIN OF LT RAM AIR DUCT. INSTALLED NEW ANGLE…
- 5 Oct 1995
Skin, cracked
PHX - DURING SCHEDULED C10 INSPECTION, FOUND L2 DOOR UPPER HINGE CUTOUT ON DOOR CRACKED AT LOWER CORNER. INSTALLED REPAIR DOUBLER PER ER 3-52-11-08. (M)
- 24 Jun 1995
Eel, disconnected
PHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTS INOPERATIVE ROW 14 THROUGH ROW 18. RECONNECTED LIGHT AT ROW 14, OPS CHECK…
- 1 Mar 1995
Eel, inop
PHX - ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE IN REAR SECTION. REPAIRED AS REQUIRED, OPS CHECK OK. (Z)
- 20 Dec 1994
Angle, corroded
PHX - DURING SCHEDULED INSPECTION, FOUND THE LT AFT LAV THRESHOLD FLOOR BEAM ANGLE CORRODED BEYOND CLEAN UP LIMITS BETWEEN STA 956.5 AND 1016. REMOVED,…
- 20 Dec 1994
Angle, corroded
DURING SCHEDULED INSPECTION, FOUND THE RT AFT LAV FWD WALL ATTACH ANGLE CORRODED AT FASTENER HOLES. REMOVED, FABRICATED AND INSTALLED NEW ANGLE PER SRM…
- 20 Dec 1994
Intercostal, cracked
PHX - DURING SCHEDULED INSPECTION, FOUND CRACKS AT THREE FASTENER HOLES IN FLOOR BEAM INTERCOSTAL, STA 927 TO 947 BL 0. FABRICATED AND INSTALLED NEW WEB AND…
- 20 Dec 1994
Floor Beam, corroded
PHX - DURING SCHEDULED INSPECTION, FOUND FLOOR BEAM TOP CAP CORRODED, STA 967.5 LBL 27. REMOVED, FABRICATED AND INSTALLED REPAIR TO FLOOR BEAM PER SRM…
- 20 Dec 1994
Floor Beam, corroded
PHX - DURING SCHEDULED INSPECTION, FOUND FLOOR BEAM TOP CAP CORRODED BEYOND CLEAN UP LIMITS AROUND FASTENER HOLE, STA 986.5 BL 0. REPAIRED PER SRM 51-70-12.…
- 20 Dec 1994
Intercostal, buckled
PHX - DURING SCHEDULED INSPECTION, FOUND INTERCOSTAL BUCKLED BETWEEN FLOOR BEAMS, STA 1006 AND 1016 RBL 27. REMOVED, FABRICATED AND INSTALLED REPAIR WEB PER…
- 20 Dec 1994
Angle, cracked
PHX - DURING SCHEDULED INSPECTION, FOUND FLOOR BOARD SUPPORT ANGLE CRACKED, STA 540 BL 0 TO LBL 2. REMOVED, FABRICATEDAND INSTALLED NEW SUPPORT ANGLE PER SRM…
- 20 Dec 1994
Former, cracked
PHX - DURING SCHEDULED INSPECTION, FOUND NR 3 FLAP TRACK FAIRING FORMER CRACKED. REMOVED, FABRICATED AND INSTALLED NEWFORMER PER SRM 51-40-02 AND 51-10-02.…