N14937
1997 Embraer EMB-145EP standard FAA →
aircraft radio
earlier registrations
1 past record
- 1997
service difficulty reports
107 reports
- 17 May 2014
Beam, corroded
DURING C-CHECK THE LT WINDSHIELD LOWER FRONT CUTOUT BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED THE CORROSION AND PERFORMED BUSHING REPAIRS IAW…
- 13 May 2014
Fitting, cracked
DURING C-CHECK THE NR 2 ENGINE FORWARD LOWER YOKE FITTING WAS FOUND TO BE CRACKED AND VERIFIED WITH EDDY CURRENT. MAINTENANCE R & R THE FITTING IAW…
- 13 May 2014
Shear Tie, corroded
DURING C-CHECK THE CARGO DOOR CUTOUT FWD SHEAR TIE WAS FOUND TO BE CORRODED AT FRAME 65, STRINGERS 15L-16L. MAINTENANCE R & R THE SHEAR CLIP IAW SRM 53-31-04.…
- 13 May 2014
Skin, corroded
DURING C-CHECK THE CENTRAL FUSELAGE LOWER SKIN WAS FOUND TO BE CORRODED AT FRAME 21, STRINGERS 21L AND 21R. MAINTENANCE R & R THE SKIN IAW EC5330-02895. THE…
- 13 May 2014
Bracket, gouged
DURING C-CHECK THE LT WINDSHIELD PILLAR BRACKET AT FRAME 10, STRINGER 5L, WAS FOUND TO BE GOUGED. MAINTENANCE R & R THE BRACKET IAW SRM 51-40-02. THE ACFT WAS…
- 13 May 2014
Stringer, cracked
DURING C-CHECK STRINGER 6R WAS FOUND TO BE CRACKED BETWEEN FRAME 12-13. MAINTENANCE R & R THE STRINGER IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO…
- 1 Apr 2014
Flapper Valve, leaking
THE CREW REPORTED THAT PILOT REPORTED MASSIVE AMOUNTS OF FLUID LOSS JUST INBD OF THE LT AILERON DURING FLIGHT WITH A HEAVY SCENT OF FUEL IN THE AREA. THE ACFT…
- 15 Jan 2014
Relay, inoperative
CREW REPORTED A NR 2 PITOT HEAT INOPERATIVE ON EICAS ACCOMPANIED BY A FAINT ELECTRICAL ODOR ON FINAL APPROACH. THE ACFT LANDED WITHOUT INCIDENT, WHERE…
- 6 Jan 2014
Skin, cracked
DURING MAINTENANCE INSPECTION, THE COCKPIT FUSELAGE SKIN WAS FOUND TO BE CRACKED AT THE UPPER AFT CORNER OF THE F/O DV WINDOW. MAINTENANCE REMOVED THE DAMAGE…
- 20 Aug 2013
Inverter, inoperative
DURNG MX INSPECTION, SEVERAL FLOOR EMERGENCY LIGHT PROXIMITY STRIPS DID NOT ILLUMINATE. MX R & R THE NR 3 EMERGENCY LIGHT INVERTER, OPERATIONALLY TESTED WITH…
- 10 Jun 2013
Tire, failed
FLIGHT 4358. RT MLG NR 3 TIRE BLEW OUT AT V1 DAMAGING OTHER ITEMS. R & R NR 3 TIRE.
- 19 Apr 2013
Skin, cracked
DURING 5A INSPECTION THE FUSELAGE CROWN SKIN WAS FOUND TO BE CRACKED ON THE LT SIDE BETWEEN THE WINDSHIELD AND DV WINDOW. MX REMOVED THA DAMAGED SECTION, AND…
- 19 Apr 2013
Skin, cracked
DURING 5A INSPECTION, THE FUSELAGE SKIN AT FR 78 BELOW STR 1R WAS FOUND TO BE CRACKED. MX REMOVED THE DAMAGED SECTION, AND PERFORMED A DOUBLER REPAIR IAW…
- 19 Apr 2013
Skin, cracked
DURING 5A INSP THE LAFT FUSELAGE SKIN WAS FOUND TO BE CRACKED AT FR78 STR 09L AROUND 1 RIVET. MX REMOVED THE DAMAGED SECTION OF SKIN AND PERFORMED A DOUBLER…
- 16 Mar 2011
Element, inoperative
IAH - FLIGHT 2804 THE CREW REPORTED AN E2 FIRE DETECTOR FAIL MESSAGE IN FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND…
- 9 Jan 2011
Windshield, arced
LCH - FLIGHT 2555, THE CREW REPORTED THAT THE CAPTAINS WINDSHIELD WAS ARCING IN FLIGHT, THE AIRCRAFT DIVERTED TO LCH WHERE IT LANDED WITHOUT INCIDENT.…
- 19 Nov 2010
Ballast, overheated
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED AN ELECTRICAL BURNING SMELL IN THE CABIN. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE…
- 11 Nov 2010
Smoke Detector, malfunctioned
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED A BAGGAGE SMOKE WARNING. THE CREW VERIFIED NO SMOKE, AND MAINTENANCE INSPECTED THE AIRCRAFT AND RESET THE…
- 11 Nov 2010
Ballast, overheated
IAH - DURING CLIMB THE CREW REPORTED AN ELECTRICAL BURNING SMELL IN THE AIR BETWEEN THE CABIN AND FLIGHT DECK. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED…
- 18 May 2010
Ballast, overheated
IAH - DURING POST FLIGHT INSPECTION, AN ELECTRICAL SMELL MID CABIN WAS REPORTED WITH NO SMOKE OBSERVED. MAINTENANCE REMOVED AND REPLACED THE BALLAST AT 11A,…
- 18 May 2010
Hose, unknown
IAH - DURING MAINTENANCE INSPECTION A BURNING SMELL WAS NOTED AT SEAT 11A AREA. MAINTENANCE REMOVED AND REPLACED SIDEWALL LIGHTS FROM 10A-12A, AND GASPER HOSE…
- 18 May 2010
Light, overheated
IAH - DURING MAINTENANCE INSPECTION A BURNING SMELL WAS NOTED AT SEAT 11A AREA. MAINTENANCE REMOVED AND REPLACED SIDEWALL LIGHTS FROM 10A-12A, AND GASPER HOSE…
- 26 Apr 2010
Connector, dirty
LRD - FLIGHT 2616, DURING PREFLIGHT INSPECTION THE CREW REPORTED THAT THE LAST THREE AISLE PATH LIGHT STRIPS AFT OF ROW 12 WERE INOPERATIVE. CONTRACT…
- 19 Apr 2010
Battery Pack, discharged
IAH - FLIGHT 2217, THE DURING POST FLIGHT THE CREW REPORTED THAT THE LAST THREE AISLE PATH LIGHT STRIPS WERE NOT ILLUMINATING. MAINTENANCE REMOVED AND…
- 2 Dec 2009
Inverter, inoperative
LCH - DURING MAINTENANCE INSPECTION THE AFT OVERHEAD EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER SIX…
- 12 Aug 2009
Battery Pack, discharged
IAH - DURING MAINTENANCE INSPECTION THE AFT THREE AISLE PATH LIGHT STRIPS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER FOUR…
- 27 Jul 2009
Sill, corroded
TYS - A/C WAS IN A C-CHECK STATUS WHEN THE LEFT FLOOR SILL WAS FOUND CORRODED AT FRAME 30 THRU 35. ALL WORK WAS ACCOMPLISHED AND WAS RELEASED AT THE END OF…
- 27 Jul 2009
Sill, corroded
TYS - A/C WAS IN A C-CHECK WHEN CORROSION WAS FOUND IN THE FLOOR SILL AT FRAME 24 THRU 30. MAINTENANCE REPLACED THE FLOOR SILL IAW EMB 135/145 SRM 51-40-02.…
- 27 Jul 2009
Floor Support, corroded
TYS - A/C WAS IN A C-CHECK STATUS WHEN CORROSION WAS FOUND ON THE LEFT OMEGA BEAM AT FRAMES 20 AND 21. MAINTENANCE REPLACED THE PREVIOUS REPAIR BY REMOVING…
- 24 Jul 2009
Sill, corroded
TYS - CORROSION WAS FOUND AROUND A NUT PLATE ON THE SERVICE DOOR AFT SILL. MAINTENANCE BLENDED OUT THE CORROSION, FABRICATED AND INSTALL A DOUBLER IAE EMB 145…
- 24 Jul 2009
Floor Support, corroded
TYS - CORROSION WAS FOUND ON THE RIGHT OMEGA BEAM AT FRAME 22 TOPCAP. MAINTENANCE REPLACED THE TOPCAP IAW EMB 135/145 SRM 51-40-07. ALODINED, PRIMED AND…
- 24 Jul 2009
Floor Support, corroded
TYS - CORROSION WAS FOUND ON THE TOPCAP AT FRAME 20. MAINTENANCE REPLACED THE TOPCAP IAW EMB 135/145 SRM 51-40-02. ALL WORK WAS ACCOMPLISHED AND WILL BE…
- 24 Jul 2009
Floor Support, corroded
TYS - CORROSION WAS FOUND ON THE CENTER OMEGA BEAM AT FRAME 22. MAINTENANCE BLENDED OUT THE CORROSION IAW EMB 135/145 SRM 51-40-01 AND CPM 51-21-04-05-06. ALL…
- 24 Jul 2009
Floor Support, corroded
TYS - CORROSION WAS FOUND AROUND THE NUT PLATES ON THE PAX DOOR ENTRYWAY AT THE AFT DIGITAL PLATE. MAINTENANCE BLENDED OUT THE LIGHT CORROSION IAW EMB 135/145…
- 24 Jul 2009
Floor Support, corroded
TYS - CORROSION WAS FOUND AROUND THE NUT PLATES ON THE FWD DIGITAL PLATE. MAINTENANCE REMOVED THE LITE CORROSION IAW EMB 135/145 SRM 51-21-10. ALL WORK WAS…
- 22 Jul 2009
Fitting, chafed
TYS - A/C CURRENTLY IN A C-CHECK STATUS WHEN INSPECTION FOUND CORROSION ON FRAME 75 VERTICAL STAB FITTING, 4 BOLT HOLES HAD SOME CORROSION. MAINTENANCE…
- 17 Jul 2009
Sign, inoperative
SERVICE DOOR EXIT SIGN INOP. REMOVED AND REPLACED EXIT SIGN IAW EMB 145 AMM 33-50-09. OPS CHECK GOOD.
- 17 Jul 2009
Fitting, cracked
CRACKED SHEAR CLIP AT FRM 10 JUST BELOW DV WINDOW. REMOVED CRACKED SHEAR CLIP, PARTIAL CRACKED FRM AND GUSSET AT FRM 10 JUST BELOW DV WINDOW. INSTALLED NEW…
- 15 Jul 2009
Sill, corroded
ACFT IN C-CHECK AND THE RT FLOOR SILL WAS FOUND CORRODED BETWEEN FR 24 THRU FR 30. MX REMOVED AND REPLACED THE FLOOR SILL IAW SRM 51-40-02. ALL WORK WAS…
- 15 Jul 2009
Sill, corroded
ACFT CURRENTLY IN A C-CHECK STATUS AND CORROSION WAS FOUND UNDER THE SVC DOOR THRESHOLD PLATE AROUND THE NUT PLATES. MX REMOVED AND REPLACED SVC DOOR…
- 13 Jul 2009
Flange, corroded
NR 2 ENG INLET MOUNTING FLANGE HAS CORROSION AT MOUNTING HOLES. CLEANED AREA AND FOUND 3 HOLES TO HAVE CORROSION. REPAIRED THE MOUNTING FLANGE HOLES IAW…
- 12 Jul 2009
Bushing, missing
RUDDER II UPPER CONTROL ROD UPPER MOUNT HAT BUSHING ON RUDDER MISSING. REMOVED AND REPLACED MOUNT IAW EC 5540-01028.
- 10 Jul 2009
Door Frame, corroded
CORROSION ON AFT LOWER END OF SERVICE DOOR CUT OUT FRAME. DOUBLER WAS MADE FROM A SPARE FRAME AND INSTALLED IAW EC 5310-01373.
- 8 Jul 2009
Floor Support, corroded
CORROSION ON CENTER OMEGA BEAM AND STEP UP AT FRM 18. CORROSION WITHIN LIMITS. BLENDED OUT, ALODINED, PRIMED, AND PAINTED.
- 8 Jul 2009
Sill, corroded
CORROSION ON LT FLOOR SILL FROM FRM 18-23. FLOOR SILL WAS REMOVED AND REPLACED.
- 8 Jul 2009
Sill, corroded
RT FLOOR SILL CORRODED BETWEEN FRM 29-35. FLOOR SILL WAS REMOVED AND REPLACED.
- 8 Jul 2009
Sill, corroded
CORROSION ON LT FLOOR SILL AT FRM 43. REMOVED AND REPLACED LT FLOOR SILL.
- 8 Jul 2009
Cap, corroded
LT LAV TOP CAP CORRDED, WITHIN LIMITS, BLENDED, ALODINED, PRIMED, AND PAINTED.
- 8 Jul 2009
Web, cracked
NR 1 ENGINE FWD/LWR YOKE WEBBING CRACKED. REMOVED AND REPLACED NR 1 ENGINE FWD/LWR YOKE WEBBING. CLOSED
- 8 Jul 2009
Cap, corroded
RT LAV TOP CAP HAS CORROSION. BLENDED MINOR CORROSION, ALODINED, PRIMED, AND PAINTED.
- 2 Jul 2009
Sill, corroded
CORROSION ON LT FLOOR SILL FROM FRM 18-23. REPLACED SILL.
- 20 Jun 2009
Ballast, overheated
IAH - FLIGHT 2414 - DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL IN ROW 1. MAINTENANCE REMOVED AND REPLACED THE LIGHTING BALLAST ABOVE ROW 1,…
- 20 Nov 2008
Controller, malfunctioned
OKC - FLIGHT 2176, THE CREW REPORTED THAT PRESSURIZATION FAILED ON DESCENT INTO OKC. THE AIRCRAFT LANDED IN OKC WITHOUT INCIDENT WHERE MAINTENANCE PLACED…
- 24 Jan 2008
Actuator, malfunctioned
IAH - FLIGHT 2618, THE CREW REPORTED A LANDING GEAR LEVER DISAGREE WHILE EN ROUTE FROM SHV TO IAH WITH A RED "X" ON THE RT MAIN GEAR INDICATOR. THE AIRCRAFT…
- 16 Dec 2007
Skin, cracked
IAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED A CRACK IN THE UPPER LT WING SKIN. THE CRACK WAS INSPECTED AND PLACED ON A 500 FLIGHT CYCLE DEFERRAL IN…
- 9 Oct 2007
Control Panel, faulty
CLE FLIGHT 2457. THE CREW REPORTED THE EMERGENCY LIGHTS WOULD TURN OFF VIA THE DIM SWITCH ON THE F/A CONTROL PANEL. MAINTENANCE INSPECTED AND REPLACED THE…
- 8 Jul 2007
Connector, unsecure
FLT 2534 - EWR - CREW REPORTED EMERGENCY LIGHT ON EXIT ROW INOP. MX MAINTENANCE RE-SECURED CONNECTOR BEHIND EMERGENCY LIGHT AND PERFORMED OPERATIONAL CHECK…
- 21 Mar 2007
Nut Plate, missing
TYS - DURING A CURRENT 1C INSPECTION FOUND A MISSING NUT PLATE FOR THE PROTRACTOR ATTACHMENT ON RUDDER 2. MAINTENANCE REPAIRED RUDDER 2 IAW EC 5540-01063. ALL…
- 13 Mar 2007
Attach Bracket, worn
RIGHT AILERON ATTACH BRACKET WORN AT THE HOLES FOR THE HAT BUSHINGS. REMOVED AND REPLACED AILERON PCA BRACKET IAW EC5750-01177. AIRCRAFT IS STILL IN C-CHECK.
- 11 Mar 2007
Attach Bracket, damaged
LEFT AILERON PCA ATTACH BRACKET HAS DAMAGED HAT BUSHING HOLES. REMOVED AND REPLACED BRACKET IAW EC5750-01177. AIRCRAFT IS STILL IN C-CHECK.
- 4 Sep 2006
Fuel Control, faulty
CREW REPORTED AIR CONDITIONING PACK NR 1 PRODUCES STRONG FUEL SMELL WHEN SELECTED ON WITH APU BLEED. SMELL RE-OCCURRED IN FLIGHT WITH ENGINE BLEED SELECTED.…
- 30 Dec 2004
Floor Support, corroded
SHV - DURING C-CHECK THE LEFT HAND OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 25. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A DOUBLER REPAIR IAW…
- 30 Dec 2004
Floorbeam, corroded
SHV - DURING C-CHECK THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 33. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A DOUBLER REPAIR IAW…
- 4 Sep 2003
Sign, inoperative
CLE FLIGHT NR 2015. THE CREW REPORTED THAT THE FORWARD MID CABIN CEILING OVER WING EMERGENCY EXIT SIGN WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE…
- 25 Jul 2003
Control Module, faulty
CREW REPORTED, AFTER TAKEOFF PITCH TRIM SYSTEM NR 1 AND NR 2 INOPERATIVE. RETURNED FOR LANDING BACK IN NEWARK. MAINTENANCE REMOVED AND REPLACED HORIZONTAL…
- 25 Jul 2003
Control Unit, inoperative
EWR FLIGHT 2403, THE CREW REPORTED THE PITCH TRIM 1/2 WAS INOPERATIVE. THE AIRCRAFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND…
- 8 Jan 2003
Odor, detected
SYR FLIGHT 2479 THE CREW REPORTED UPON APU START THERE WAS A STRONG ELECTRICAL ODOR IN THE COCKPIT. THE ODOR DISSIPATED ON SHUTDOWN. MAINTENANCE RELEASED THE…
- 11 Oct 2002
Flap Track, cracked
DURING C CHECK INSPECTION, RT HAND OUTBOARD FLAP CENTER TRACK WAS FOUND TO HAVE A CRACK DUE TO LIGHTING STRIKE. MAINTENANCE REPAIRED DAMAGE IAW CONTINENTAL…
- 9 Oct 2002
Floorbeam, corroded
DURING C CHECK INSPECTION, CORROSION WAS FOUND AT CENTER FLOORBEAM SUPPORT RAMP BETWEEN FRAMES 18 AND 20. MAINTENANCE REMOVED DAMAGED SECTION, PERFORMED AN…
- 6 Oct 2002
Skin, dented
DURING C CHECK, DENT WAS FOUND ON SKIN DOUBLER JUST BELOW PANEL 113EL. MAITENANCE REMOVED DAMAGE AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM 53-11-01. THE…
- 6 Oct 2002
Floorbeam, corroded
DURING C CHECK INSPECTION, LT LATERAL FLOORBEAM WAS FOUND TO HAVE CORROSION AT RE-ENFORCEMENT ANGLE BETWEEN FRAMES 19 AND 21. MAINTENANCE REMOVED DAMAGE AND…
- 6 Oct 2002
Floorbeam, corroded
SHV- DURING C CHECK INSPECTION CENTER FLOORBEAM BUTT STRAP BETWEEN FRAMES 59 AND 61 WAS FOUND TO HAVE CORROSION ON NUTPLATES AND NUTPLATES HOLES. MAINTENANCE…
- 4 Oct 2002
Sill, corroded
DURING C CHECK INSPECTION CORROSION WAS FOUND ON NUTPLATE AT LT SILL BETWEEN FRAMES 20 AND 23. MAINTENANCE REMOVED AND REPLACED LT SILL BETWEEN FRAMES 18 AND…
- 4 Oct 2002
Floorbeam, corroded
SHV- DURING C CHECK THE CENTER FLOORBEAM WAS FOUND TO HAVE CORROSION AT GALLEY MOUNT HOLES BETWEEN FRAMES 18 AND 23. MAINTENANCE REMOVED AND REPLACED CENTER…
- 4 Oct 2002
Floorbeam, corroded
DURING C CHECK INSPECTION BUTTSRAP ON CENTER FLOORBEAM WAS FOUND TO HAVE CORROSION BETWEEN FRAMES 18 AND 23. MAINTENANCE REMOVED AND REPLACED CENTER FLOORBEAM…
- 4 Oct 2002
Angle, cracked
DURING C CHECK INSPECTION SPLICED ANGLE AT LT FLOORBEAM BETWEEN FRAMES 16 AND 17 WAS FOUND CRACKED. MAINTENANCE REMOVED DAMAGE AND PERFORMED AN ANGLE REPAIR…
- 4 Oct 2002
Floorbeam, corroded
SHV-DURING C CHECK FLOORBEAM DOUBLER AT FWD CARGO PARTITION WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED AND REPLACED DAMAGED DOUBLER IAW EMB 145 SRM…
- 4 Oct 2002
Floorbeam, corroded
DURING C CHECK INSPECTION NUTPLATE WAS FOUND CORRODED ON CENTER FLOORBEAM AT FRAME 18. MAINTENANCE REMOVED AND REPLACED FLOORBEAM BETWEEN FRAMES 16 AND 24 IAW…
- 4 Oct 2002
Floorbeam, corroded
SHV-DURING C CHECK INSPECTION DOUBLER ON RT LATERAL FLOORBEAM AT FRAME 20 WAS FOUND WITH CORROSION. MAINTENANCE REMOVED AND REPLACED DAMAGED DOUBLER IAW EMB…
- 4 Oct 2002
Floorbeam, corroded
SHV-DURING C CHECK INSPECTION NUTPLATE WAS FOUND WITH CORROSION ON CENTER FLOORBEAM AT FRAME 22. MAINTENANCE REMOVED DAMAGE AND REPLACED FLOORBEAM BETWEEN…
- 4 Oct 2002
Floorbeam, corroded
SHV-DURING C CHECK INSPECTION, LT LATERAL FLOORBEAM AROUND NUTPLATE HOLES WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED DAMAGE AND PERFORMED A FLOORBEAM…
- 4 Oct 2002
Butt Strap, corroded
DURING C CHECK INSPECTION, CORROSION AND PITTING WAS FOUND AROUND RIVETS ON BUTTSTRAP BETWEEN FRAMES 59 AND 61. MAITENANCE REMOVED AND REPLACED AFFECTED…
- 4 Oct 2002
Floorbeam, corroded
SHV-DURING C CHECK, LT CARGO SILL FLOORBEAM WAS FOUND TO HAVE CORROSION. MAITENANCE REMOVED AND REPLACED AFFECTED SILL FLOORBEAM IAW EMB SRM 57-220-03, SRM…
- 4 Oct 2002
Floorbeam, corroded
DURING C CHECK INSPECTION, RT FLOORBEAM BUTT STRAP BETWEEN FRAMES 59 AND 61 WAS FOUND TO HAVE CORROSION IN NUTPLATE HOLES. MAITENANCE REMOVED AND REPLACED…
- 4 Oct 2002
Bushing, damaged
DURING C CHECK, ALL HAT BUSHINGS ON THE RUDDER ATTACHING BRACKETS WERE FOUND DAMAGED. MAINTENANCE REMOVED AND REPLACED ALL HAT BUSHINGS ON RUDDEDR ATTACHING…
- 4 Oct 2002
Floorbeam, corroded
SHV DURING C CHECK, NUTPLATE HOLES WERE FOUND WITH CORROSION ON LT LATERAL FLOORBEAM BETWEEN FRAMES 15 AND 17. MAITENANCE REMOVED DAMAGED SECTION AND…
- 4 Oct 2002
Floorbeam, corroded
SHV DURING C CHECK INSPECTION, THE RT FLOORBEAM AT FRAME 20 WAS FOUND TO HAVE CORROSION AT NUTPLATE HOLES AND UNDER DOUBLER. MAINTENANCE REMOVED DAMAGED…
- 4 Oct 2002
Sill, corroded
DURING C CHECK CORROSION WAS FOUND ON NUTPLATE HOLES ON LT SILL BETWEEN FRAMES 20 AND 23. MAINTENANCE REMOVED AND REPLACED AFFECTED SILL IAW EMB 145 SRM…
- 4 Oct 2002
Angle, gouged
SHV DURING C CHECK INSPECTION SUPPORT ANGLE WAS FOUND GOUGED ON NR 1 ENGINE LOWER COWLING JUST AFT OF MOST FOWARD PIVOT POINT. MAINTENACE REMOVED DAMAGED AREA…
- 4 Oct 2002
Angle, gouged
SHV DURING C CHECK INSPECTION GOUGE WAS FOUND ON NR 1 ENGINE LOWER COWLING AFT OF ENGINE DRAIN. MAINTENANCE REMOVED DAMAGED SETION AND PERFORMED AN ANGLE…
- 27 Jul 2002
Connector, loose
IAH - CREW REPORTED THAT ONE OF THE FLOOR PROXIMITY EMERGENCY LIGHT STRIPS DID NOT ILLUMINATE. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE NR 3 FLOOR…
- 27 Jul 2002
Light, malfunctioned
MEM - CREW REPORTED THAT THE EMERGENCY LIGHTING STAYED ON WITH SWITCH SELECTED TO THE OFF POSITION. AN ELECTRICAL RESET OF THE SYSTEM WAS ACCOMPLISHED AND THE…
- 18 Jul 2002
Control Unit, malfunctioned
IAH- FLIGHT 3935, DURING CLIMB THE CREW NOTED THAT THE GEAR WOULD NOT RETRACT AS SELECTED, GEAR HANDLE DISAGREE. THE CREW RETURNED THE GEAR HANDLE TO THE DOWN…
- 30 Nov 2001
Fire Bottle, defective
CLE FLIGHT 3157 THE CREW REPORTED A ENGINE 1 (2) EXTINGUISHER BOTTLE A INOP MESSAGE DURING FLIGHT. THE MESSAGE WENT OUT DURING DESCENT. MAINTENANCE REPLACED…
- 27 Aug 2001
Harness, defective
CLE FLIGHT 4109 THE CREW REPORTED SMOKE APPEARED FROM CABIN LIGHTS ABOVE SEAT 1A. MAINTENANCE INSPECTED AND REPLACED THE UPPER CABIN LIGHT HARNESS ASSEMBLY.…
- 16 May 2001
Light, smoke
IAH - FLIGHT 4128, THE CREW REPORTED THAT THE LAV LIGHT EMITTED A BURNING ODOR. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT. MAINTENANCE PLACED THE LAV ON MEL…
- 14 Jan 2001
Light, inoperative
IAH - DURING C-CHECK INSPECTION, THE RIGHT HAND FORWARD EXTERNAL EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE…
- 14 Jan 2001
Charger, inoperative
IAH - DURING C-CHECK INSPECTION, THE EMERGENCY LIGHT ON PANEL 243DLC WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED EMERGENCY…
- 14 Jan 2001
Bulb, burned out
IAH - DURING C-CHECK INSPECTION, THE PASSENGER DOOR EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT BULB IN…
- 3 Jan 2001
Hinge, corroded
IAH - DURING C-CHECK INSPECTION, THE RIGHT VERTICAL STABILIZER FITTING HINGE SUPPORT FOR THE HORIZONTAL STAB WAS FOUND TO BE CORRODED IN THE PIN BORE.…
- 2 Jan 2001
Sill, corroded
IAH - DURING C-CHECK INSPECTION, THE CARGO DOOR SILL PLATE WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED SILL PLATE IAW EMB145 SRM…
- 2 Dec 2000
Battery Pack, inoperative
BNA - DURING SERVICE CHECK, MAINTENANCE FOUND THE LEFT AND RIGHT OVERWING EXTERIOR EMERGENCY LIGHTS TO BE INOPERATIVE AND WERE PLACED ON CATEGORY C MEL IAW…
- 2 Dec 2000
Thrust Reverser, malfunctioned
CREW REPORTED THAT THE NUMBER ONE ENGINE THRUST REVERSER OPEN LIGHT ILLUMINATED IN FLIGHT. A/C RETURNED TO IAH WITHOUT INCIDENT. MX INSPECTED, AND…
- 18 Jan 2000
Skin, damaged
EWR - THE RIGHT FORWARD FUSELAGE SKIN WAS FOUND TO HAVE GROUND DAMAGE. THE AIRCRAFT WAS FERRIED TO IAH WHERE MAINTENANCE PERFORMED A DOUBLER REPAIR IAW…
- 9 Sep 1999
Actuator, broken
EFD - FLT 938A - THE CREW REPORTED ENGINE ONE REVERSER DISAGREE, ENGINE ONE REVERSER FAIL, NR 1 REVERSER LEVER INOPERATIVE DURING TAXI, AND THE NR 1 UPPER…
- 16 Jun 1999
Battery Charger, inoperative
IAH - DURING C-CHECK INSPECTION, THE SERVICE DOOR EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED EMERGENCY…
- 27 Dec 1998
Blade, damaged
CLE - DURING A SCHEDULED INSPECTION, THE RIGHT HAND ENGINE TURBINE BLADES WERE FOUND TO HAVE DAMAGED EDGES AND APPEAR TO BE RUBBING. THE DAMAGE WAS FOUND…